Evidence map›Paper›PMID 30542557›Full record

ArticleChemical science2018

On-demand quantitative SERS bioassays facilitated by surface-tethered ratiometric probes.

Kun Zhang, Yuning Wang, Meiling Wu, Yujie Liu, Dongyun Shi, Baohong Liu

Open access · diamondAbstract read
In one paragraph

Article in Chemical science, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. A Biomimetic Plasmonic Nanoreactor for Reliable Metabolite Detection.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2020
    Article
  5. Article
  6. Magnetic Nanomotor-Based Maneuverable SERS Probe.Research (Washington, D.C.) · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Kun ZhangDepartment of Chemistry , Shanghai Stomatological Hospital , State Key Laboratory of Molecular Engineering of Polymers , Institutes of Biomedical Sciences , Collaborative Innovation Center of Chemistry for Energy Materials , Fudan University , Shanghai 200438 , China . Email: bhliu@fudan.edu.cn.
Yuning WangDepartment of Chemistry , Shanghai Stomatological Hospital , State Key Laboratory of Molecular Engineering of Polymers , Institutes of Biomedical Sciences , Collaborative Innovation Center of Chemistry for Energy Materials , Fudan University , Shanghai 200438 , China . Email: bhliu@fudan.edu.cn.
Meiling WuDepartment of Biochemistry and Molecular Biology , Shanghai Medical College of Fudan University , Shanghai 200032 , China.
Yujie LiuDepartment of Chemistry , Shanghai Stomatological Hospital , State Key Laboratory of Molecular Engineering of Polymers , Institutes of Biomedical Sciences , Collaborative Innovation Center of Chemistry for Energy Materials , Fudan University , Shanghai 200438 , China . Email: bhliu@fudan.edu.cn.
Dongyun ShiDepartment of Biochemistry and Molecular Biology , Shanghai Medical College of Fudan University , Shanghai 200032 , China.
Baohong LiuDepartment of Chemistry , Shanghai Stomatological Hospital , State Key Laboratory of Molecular Engineering of Polymers , Institutes of Biomedical Sciences , Collaborative Innovation Center of Chemistry for Energy Materials , Fudan University , Shanghai 200438 , China . Email: bhliu@fudan.edu.cn.ORCID 0000-0002-0660-8610
Fudan University · CNShanghai Medical College of Fudan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Reliable and user-friendly sensing of target analytes in complex biofluids is of fundamental importance to biological science and medicine. Surface-enhanced Raman spectroscopy (SERS) has proven to be capable of detecting molecules with high sensitivity, but achieving robust quantitative detection remains a challenge mainly because of the severe signal fluctuation at electromagnetic hot spots. Here, we describe an on-demand and quantitative SERS strategy for metabolite profiling based on a chip-based sensing device that adopts stable and surface-tethered small-molecule probes as Raman reporters. These probes with a ratiometric response allow for sensitive and reproducible SERS detection by offering an internal calibration to correct the signal fluctuation caused by the spatiotemporal variation of assay conditions. Meanwhile, the chip-based sensing scheme makes time-separated on-demand detection possible. Ultimately, due to the flexibility in choosing diverse ratiometric Raman probes, we expect the proposed quantitative SERS sensing concept to be useful for studies in the fields of cell biology and clinical diagnosis.

Identifiers

PMID30542557
PMCPMC6238711
OpenAlexW2888950269

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked