Evidence map›Paper›PMID 30540773›Full record

ArticlePloS one2018

Spiroergometric measurements under increased inspiratory oxygen concentration (FIO2)-Putting the Haldane transformation to the test.

Stephan Lang, Robert Herold, Alexander Kraft, Volker Harth, Alexandra M Preisser

Abstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. The effect of the fraction of inspired oxygen on the NIRS-derived deoxygenated hemoglobin "breakpoint" during ramp-incremental test.American journal of physiology. Regulatory, integrative and comparative physiology · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stephan LangInstitute for Occupational and Maritime Medicine (ZfAM), University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Robert HeroldInstitute for Occupational and Maritime Medicine (ZfAM), University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Alexander KraftInstitute for Occupational and Maritime Medicine (ZfAM), University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Volker HarthInstitute for Occupational and Maritime Medicine (ZfAM), University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Alexandra M PreisserInstitute for Occupational and Maritime Medicine (ZfAM), University Medical Center Hamburg-Eppendorf, Hamburg, Germany.ORCID 0000-0002-2957-3545

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Spiroergometric measurements of persons who require oxygen insufflation due to illness can be performed under conditions of increased inspiratory oxygen concentration (FIO2). This increase in FIO2, however, often leads to errors in the calculation of oxygen consumption ([Formula: see text]). These inconsistencies are due to the application of the Haldane Transformation (HT), an otherwise indispensable correction factor in the calculation of [Formula: see text] that becomes inaccurate at higher FIO2 concentrations. A possible solution to this problem could be the use of the 'Eschenbacher transformation' (ET) as an alternative correction factor. This study examines the concentration of FIO2 at which the HT and the ET are valid, providing plausible data of oxygen consumption corresponding to the wattage achieved during cycle ergometry. Ten healthy volunteers underwent spiroergometric testing under standard conditions (FIO2 = 20.9%), as well as at FIO2 = 40% and 80%. When compared with the predicted values of [Formula: see text], as calculated according to Wasserman et al. (2012), the data obtained show that both the HT and ET are valid under normal conditions and at an increased FIO2 of 40%. At FIO2 concentrations of 80%, however, the [Formula: see text] values provided by the HT begin to lose plausibility, whereas the ET continues to provide credible results. We conclude that the use of the ET in place of the HT in spiroergometric measurements with increased FIO2 allows a reliable evaluation of stress tests in patients requiring high doses of supplemental oxygen.

Indexed as

AdultExercise TestHealthy VolunteersHumansInsufflationIntermittent Positive-Pressure BreathingMaleOxygenOxygen ConsumptionOxygen

Identifiers

PMID30540773
PMCPMC6291083

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.