ArticleJournal of anesthesia2019
Surface contamination in the operating room: use of adenosine triphosphate monitoring.
Article in Journal of anesthesia, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Evaluation of disinfection methods and effects for handwashing sinks contaminated with Pseudomonas aeruginosa.Scientific reports · 2026Article
- Assessment of Soiling on Highly Touched Clinical Surfaces in Intensive Care Units.Florence Nightingale journal of nursing · 2023Article
- An alternative approach for the decontamination of hospital settings.Journal of infection and public health · 2020Article
- Development and Improvement of an Effective Method for Air and Surfaces Disinfection with Ozone Gas as a Decontaminating Agent.Medicina (Kaunas, Lithuania) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeWe prospectively investigated contamination of high-contact surfaces in the operating room (OR) using adenosine triphosphate (ATP) monitoring. We tested whether contamination would increase from morning (AM) to afternoon (PM), despite cleaning between cases. Second, we compared the degree of OR contamination to non-OR control sites.
methodsORs with high case volumes were selected for the study. Ten sites in each OR were swabbed using the AccuPoint
resultsEighty morning and 70 afternoon samples were obtained from 8 ORs. Apart from the OR floor, laryngoscope handles had the highest level of morning contamination (1204 RLUs, interquartile range 345, 2603), with 75% of AM samples and 100% of PM samples exceeding 400 RLUs. This contamination was comparable to hospital toilet seats (87% of samples exceeding 400 RLUs). No sites showed statistically significant increases in contamination from AM to PM.
conclusionApart from the OR floors, laryngoscope handles emerged as a key OR site where improved cleaning practices may reduce cross-contamination risk. While some sites showed increased contamination over the course of the day, none of these met statistical significance thereby offering tentative evidence that current cleaning practices during case turnover are effective for most sites.