Evidence map›Paper›PMID 30537896›Full record

Observational studyThe journal of vascular access2019

Predictors of venous stenosis or occlusion following first transvenous cardiac device implantation: Prospective observational study.

Andrzej Cacko, Eliza Kozyra-Pydyś, Monika Gawałko, Grzegorz Opolski, Marcin Grabowski

Open access · hybridAbstract readObservational Study
In one paragraph

Observational study in The journal of vascular access, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 21 citations in OpenAlex.

  1. Outcomes of Intravenous Normal Saline Infusion Pre-Cardiac Implantable Electronic Devices Versus No Infusion in Fasting.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2026
    Article
  2. Review
  3. A Comprehensive Review of Catheter-Related Thrombosis.Journal of clinical medicine · 2024
    Review
  4. Observational
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Andrzej Cacko1 Department of Medical Informatics and Telemedicine, Medical University of Warsaw, Warsaw, Poland.
Eliza Kozyra-Pydyś2 1st Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Monika Gawałko2 1st Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Grzegorz Opolski2 1st Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Marcin Grabowski2 1st Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Medical University of Warsaw · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionVenous stenosis or occlusion related to an intracardiac device is a well-known complication of that procedure. There are numerous studies tried to determine predictors of venous stenosis or occlusion; however, most of them investigate the venous system prior to device upgrade, generator replacement, or transvenous lead extraction. Therefore, we aimed to assess the prevalence and determine the predictors of venous stenosis or occlusion following first transevnous cardiac device implantation.

methodsObservational, prospective study included 71 consecutive patients admitted for first transvenous cardiac device implantation. All patients were followed up for 6 months after operation.

resultsImplanted device systems comprised cardioverter defibrillator (n = 26), single-chamber or dual-chamber pacemakers (n = 34), and biventricular pacemakers (n = 11); 88.5% of implantable cardioverter defibrillator leads were single-coils and 11.5% were dual-coils. The incidence of venous stenosis or occlusion within 6-month follow-up was 21.1%. Multivariate logistic regression showed that only diabetes or prediabetes (p = 0.033, odds ratio: 0.17, 95% confidence interval: 0.04-0.87), prolonged procedure time (p = 0.046, odds ratio: 4.54, 95% confidence interval: 1.01-20.12), and perioperative complications (p = 0.021, odds ratio: 7.04, 95% confidence interval: 1.35-36.85) were predictors of venous stenosis or occlusion.

conclusionProlonged implantation time (>60 min) and perioperative complications are associated with an increased risk of venous stenosis or occlusion, whereas diabetes and prediabetes significantly reduce the risk of venous stenosis or occlusion.

Indexed as

Defibrillators, ImplantablePacemaker, ArtificialVeinsAgedAged, 80 and overCardiac Resynchronization Therapy DevicesConstriction, PathologicDiabetes MellitusFemaleHumansMaleMiddle AgedPolandPrediabetic StatePrevalenceProspective StudiesCardiac implanted electronic devicesdiabetesprediabetesrisk factorsvein stenosis or occlusion

Identifiers

PMID30537896
PMCPMC6699062
OpenAlexW2904355583

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.