Evidence map›Paper›PMID 30537225›Full record

ArticleMedical physics2019

Technical Note: A method for quality assurance of landmark sets for use in evaluation of deformable image registration accuracy of lung parenchyma.

Christopher L Guy, Elisabeth Weiss, Nuzhat Jan, Gary E Christensen, Geoffrey D Hugo

Abstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Christopher L GuyDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, VA, 23298, USA.
Elisabeth WeissDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, VA, 23298, USA.
Nuzhat JanDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, VA, 23298, USA.
Gary E ChristensenDepartment of Electrical and Computer Engineering, Department of Radiation Oncology, University of Iowa, Iowa City, IA, 52242, USA.
Geoffrey D HugoDepartment of Radiation Oncology, Washington University in St. Louis, St. Louis, MO, 63110, USA.

Funding

Viral VectorP30CA086862 · NCI · UNIVERSITY OF IOWA · PI Douglas Robert Spitz · 2000 to 2026
$70.0M
Consistent anatomy registration for lung cancer adaptive radiation therapyR01CA166119 · NCI · WASHINGTON UNIVERSITY · PI HUGO, GEOFFREY D · 2013 to 2017
$1.5M
National Cancer Institute of the National Institutes of Health R01CA166119NCI NIH HHS R01 CA166119
6 · The paper itself

Abstract

purposeTo develop a quality control method to improve the accuracy of corresponding landmark sets used for deformable image registration (DIR) evaluation in the lung parenchyma.

methodsAn iterative workflow was developed as a method for quality assurance of landmark sets. Starting with the initial landmark set for a given image pair, a landmark-based deformation was applied to one of the images. A difference image and a color overlay were generated using the deformed image and the other image of the pair. Inspection of these generated images at locations of landmarks allowed for the identification of misplaced landmarks. The observer responsible for creating the initial landmark set was tasked with review and revision of points flagged by the quality assurance procedure. Using the updated landmark sets, the process was repeated until all points were acceptable to the reviewer.

resultsEighteen landmark sets, containing a mean (SD) of 170 (31) landmarks, were created using CT images from non-small cell lung cancer patients exhibiting large geometric changes and atelectasis resolution, making landmark specification challenging. Following the quality assurance procedure, the final landmark sets contained a mean (SD) of 165 (25) landmarks, as points too difficult to match were removed and points were added to regions deficient in landmarks. For landmark sets in which changes were made, maximum and mean differences in landmark positions before and after quality assurance ranged between 8.7-81.5 mm and 0.3-9.6 mm, respectively.

conclusionsAn effective method for improving the accuracy of landmark correspondence was presented. This quality assurance approach enables more accurate evaluation of DIR for lung parenchyma in clinical image pairs in the absence of a ground truth deformation and may be applicable to other feature-rich anatomical sites.

Indexed as

Carcinoma, Non-Small-Cell LungFeasibility StudiesHumansImage Processing, Computer-AssistedLungLung NeoplasmsQuality ControlTomography, X-Ray Computed

Identifiers

PMID30537225
PMCPMC6367034

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.