Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Do AI-based contouring algorithms influence physicians in the online adaptive radiotherapy of patients with bladder cancer?Technical innovations & patient support in radiation oncology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeTo develop a quality control method to improve the accuracy of corresponding landmark sets used for deformable image registration (DIR) evaluation in the lung parenchyma.
methodsAn iterative workflow was developed as a method for quality assurance of landmark sets. Starting with the initial landmark set for a given image pair, a landmark-based deformation was applied to one of the images. A difference image and a color overlay were generated using the deformed image and the other image of the pair. Inspection of these generated images at locations of landmarks allowed for the identification of misplaced landmarks. The observer responsible for creating the initial landmark set was tasked with review and revision of points flagged by the quality assurance procedure. Using the updated landmark sets, the process was repeated until all points were acceptable to the reviewer.
resultsEighteen landmark sets, containing a mean (SD) of 170 (31) landmarks, were created using CT images from non-small cell lung cancer patients exhibiting large geometric changes and atelectasis resolution, making landmark specification challenging. Following the quality assurance procedure, the final landmark sets contained a mean (SD) of 165 (25) landmarks, as points too difficult to match were removed and points were added to regions deficient in landmarks. For landmark sets in which changes were made, maximum and mean differences in landmark positions before and after quality assurance ranged between 8.7-81.5 mm and 0.3-9.6 mm, respectively.
conclusionsAn effective method for improving the accuracy of landmark correspondence was presented. This quality assurance approach enables more accurate evaluation of DIR for lung parenchyma in clinical image pairs in the absence of a ground truth deformation and may be applicable to other feature-rich anatomical sites.