ArticleJournal of anatomy2019
Physiological in vitro sacroiliac joint motion: a study on three-dimensional posterior pelvic ring kinematics.
Article in Journal of anatomy, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 40 citations in OpenAlex.
- Significance of fiber orientation in the interosseous sacroiliac ligament: An anatomical and histological study of the implications of its mechanical adaptation.Journal of anatomy · 2026Article
- Sex and age differences in regional distribution of bone mineral density in the pubic symphysis using Computed Tomography Osteoabsorptiometry (CT-OAM).BMC musculoskeletal disorders · 2026Article
- A rig for in vitro testing of the lumbar spine and pelvis simulating posterior, anterior and oblique trunk muscles.Scientific reports · 2025Article
- Sacroiliac joint auricular surface morphology modulates its mechanical environment.Journal of anatomy · 2025Article
- Sex-specific trunk movement coordination in participants with low-back pain and asymptomatic controls.Frontiers in sports and active living · 2025Article
- Effects of lumbosacral and lumbopelvic fixation and fusion on hip joint motor function: a single-center prospective cohort study using gait analysis.Frontiers in surgery · 2025Article
- Comparison of a Novel Posterior Integrated Transfixation Sacroiliac Joint Fusion Approach to the Posterolateral and Lateral Approaches: A Cadaveric Biomechanical and Computational Analysis of the Fixation, Invasiveness, and Fusion Area.Medical devices (Auckland, N.Z.) · 2024Article
- Influence of size and shape of the auricular surfaces on subchondral bone density distribution in the sacroiliac joint.Journal of anatomy · 2023Article
- Numerical analysis of the effects of padded pelvic belts as a treatment for sacroiliac joint dysfunction.Bio-medical materials and engineering · 2023Article
- Sacroiliac innervation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022Article
- Sacrospinous and sacrotuberous ligaments influence in pelvis kinematics.Journal of anatomy · 2022Article
- Comparative Analysis of Optoelectronic Accuracy in the Laboratory Setting Versus Clinical Operative Environment: A Systematic Review.Global spine journal · 2022Article
- Reconstruction with 3D-printed prostheses after type I + II + III internal hemipelvectomy: Finite element analysis and preliminary outcomes.Frontiers in bioengineering and biotechnology · 2022Article
- Article
- Biomechanical analysis of sacroiliac joint motion following oblique-pulling manipulation with or without pubic symphysis injury.Frontiers in bioengineering and biotechnology · 2022Article
- A Tribological Comparison of Facet Joint, Sacroiliac Joint, and Knee Cartilage in the Yucatan Minipig.Cartilage · 2021Article
- Accuracy of Robotic-Assisted Spinal Surgery-Comparison to TJR Robotics, da Vinci Robotics, and Optoelectronic Laboratory Robotics.International journal of spine surgery · 2021Article
- Biomechanical analysis of the number of implants for the immediate sacroiliac joint fixation.Spine deformity · 2021Article
- Finite element analysis of load transition on sacroiliac joint during bipedal walking.Scientific reports · 2020Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The sacroiliac joint (SIJ) is a well-known source of low back and pelvic pain, of increasing interest for both conservative and surgical treatment. Alterations in the kinematics of the pelvis have been hypothesized as a major cause of SIJ-related pain. However, definitions of both the range and the extent of physiological movement are controversial, and there are no clear baseline data for pathological alterations. The present study combined a novel biomechanical setup allowing for physiological motion of the lumbosacral transition and pelvis without restricting the SIJ movement in vitro, combined with optical image correlation. Six fresh human pelvises (81 ± 10 years, three females, three males) were tested, with bodyweight-adapted loading applied to the fifth lumbar vertebra and both acetabula. Deformation at the lumbopelvises was determined computationally from three-dimensional image correlation data. Sacroiliac joint motion under the loading of 100% bodyweight primarily consisted of a z-axis rotation (0.16°) and an inferior translation of the sacrum relative to the ilium (0.32 mm). Sacroiliac joint flexion-extension rotations were minute (< 0.02°). Corresponding movements of the SIJ were found at the lumbosacral transition, with an anterior translation of L5 relative to the sacrum of -0.97 mm and an inferior translation of 0.11 mm, respectively. Moreover, a flexion of 1.82° was observed at the lumbosacral transition. Within the innominate bone and at the pubic symphysis, small complementary rotations were seen around a vertical axis, accounting for -0.10° and 0.11°, respectively. Other motions were minute and accompanied by large interindividual variation. The present study provides evidence of different SIJ motions than reported previously when exerted by physiological loading. Sacroiliac joint kinematics were in the sub-degree and sub-millimeter range, in line with previous in vivo and in vitro findings, largely limited to the sagittal rotation and an inferior translation of the sacrum relative to the ilium. This given physiological loading scenario underlines the relevance of the lumbosacral transition when considering the overall motion of the lumbopelvis, and how relatively little the other segments contribute to overall motion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.