Evidence map›Paper›PMID 30536124›Full record

ArticleInternational journal of implant dentistry2018

Effectiveness and compliance of an oscillating-rotating toothbrush in patients with dental implants: a randomized clinical trial.

Giuseppe Allocca, Diana Pudylyk, Fabrizio Signorino, Giovanni Battista Grossi, Carlo Maiorana

Open access · diamondAbstract read
In one paragraph

Article in International journal of implant dentistry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Giuseppe AlloccaCenter for Edentulism and Jaw Atrophies, Maxillofacial Surgery and Dentistry Unit, Fondazione IRCCS Cà Granda - Ospedale Maggiore Policlinico, University of Milan, Via Commenda 10, 20122, Milan, Italy.
Diana PudylykCenter for Edentulism and Jaw Atrophies, Maxillofacial Surgery and Dentistry Unit, Fondazione IRCCS Cà Granda - Ospedale Maggiore Policlinico, University of Milan, Via Commenda 10, 20122, Milan, Italy.
Fabrizio SignorinoCenter for Edentulism and Jaw Atrophies, Maxillofacial Surgery and Dentistry Unit, Fondazione IRCCS Cà Granda - Ospedale Maggiore Policlinico, University of Milan, Via Commenda 10, 20122, Milan, Italy. fabroski@hotmail.it.ORCID http://orcid.org/0000-0002-5232-0909
Giovanni Battista GrossiOral Surgery, Maxillofacial Surgery and Dentistry Unit, Fondazione IRCCS Cà Granda - Ospedale Maggiore Policlinico, University of Milan, Via Commenda 10, 20122, Milan, Italy.
Carlo MaioranaCenter for Edentulism and Jaw Atrophies, Maxillofacial Surgery and Dentistry Unit, Fondazione IRCCS Cà Granda - Ospedale Maggiore Policlinico, University of Milan, Via Commenda 10, 20122, Milan, Italy.
University of Milan · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this randomized clinical trial was to assess the efficacy of an oscillating-rotating toothbrush in reducing plaque and inflammation around dental implants.

methodsEighty patients presenting dental implants were enrolled in this study and assigned randomly to two different groups: 40 patients in the test group and 40 in the control one. Each patient in the test group received an oscillating-rotating toothbrush while in the control group patients kept using the manual toothbrush. Furthermore, the test group received a special toothbrush head designed for dental implants and another one for natural teeth. Domiciliary oral hygiene instructions were given to both groups. Periodontal parameters like plaque index (PI), bleeding on probing (BoP), and probing pocket depth (PPD) were recorded at the baseline and after 1 and 3 months.

resultsAt the end of the study, the difference of plaque and bleeding indices with the baseline was statistically significant for both test and control groups (P < 0.0001). Implant sites showed higher values of both BoP and PI when compared to the natural teeth. In the second part of the study, comparing the 1-3-month period, the oscillating-rotating toothbrush was effective in reducing new plaque formation (P < 0.0001) and bleeding (P < 0.0001) both at the implant sites and the dental sites comparing to manual ones (P > 0.05). No significant differences were appreciated concerning the PPD.

conclusionsThe oscillating-rotating toothbrush can be successfully used for the plaque and bleeding control of the peri-implant tissues.

Indexed as

Dental implantDomiciliary hygieneElectric toothbrushImplant maintenanceOral hygiene

Identifiers

PMID30536124
PMCPMC6286907
OpenAlexW2900443303

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.