Lalida Tuntipumiamorn, Puangpen Tangboonduangjit, Taweap Sanghangthum, Rattapol Rangseevijitprapa, Chirasak Khamfongkhruea, Thida Niyomthai, Boonrut Vuttiprasertpong, Supranee Supanant, Nongnuch Chatchaipaiboon, Porntip Iampongpaiboon and 2 more

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Lalida TuntipumiamornDivision of Radiation Oncology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Puangpen TangboonduangjitDepartment of Diagnostic and Therapeutic Radiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Taweap SanghangthumDivision of Radiation Oncology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Rattapol RangseevijitprapaDivision of Radiation Oncology, Faculty of Medicine, Srinagarind Hospital, Khon Kaen University, Khon Kaen, Thailand.
Chirasak KhamfongkhrueaChulabhorn Cancer Center, Chulabhorn Hospital, Bangkok, Thailand.
Thida NiyomthaiNational Cancer Institute, Bangkok, Thailand.
Boonrut VuttiprasertpongBumrungrad Hospital, Bangkok, Thailand.
Supranee SupanantWattanosoth Hospital, Bangkok, Thailand.
Nongnuch ChatchaipaiboonWattanosoth Hospital, Bangkok, Thailand.
Porntip IampongpaiboonDivision of Radiation Oncology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Pitchayut NakkrasaeDivision of Radiation Oncology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Tanwiwat JaikunaDivision of Radiation Oncology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimIn this study, an accuracy survey of intensity-modulated radiation therapy (IMRT) and volumetric arc radiation therapy (VMAT) implementation in radiotherapy centers in Thailand was conducted.

backgroundIt is well recognized that there is a need for radiotherapy centers to evaluate the accuracy levels of their current practices, and use the related information to identify opportunities for future development. MATERIALS AND

methodsAn end-to-end test using a CIRS thorax phantom was carried out at 8 participating centers. Based on each center's protocol for simulation and planning, linac-based IMRT or VMAT plans were generated following the IAEA (CRP E24017) guidelines. Point doses in the region of PTVs and OARs were obtained from 5 ionization chamber readings and the dose distribution from the radiochromic films. The global gamma indices of the measurement doses and the treatment planning system calculation doses were compared.

resultsThe large majority of the RT centers (6/8) fulfilled the dosimetric goals, with the measured and calculated doses at the specification points agreeing within ±3% for PTV and ±5% for OARS. At 2 centers, TPS underestimated the lung doses by about 6% and spinal cord doses by 8%. The mean percentage gamma pass rates for the 8 centers were 98.29 ± 0.67% (for the 3%/3 mm criterion) and 96.72 ± 0.84% (for the 2%/2 mm criterion).

conclusionsThe 8 participating RT centers achieved a satisfactory quality level of IMRT/VMAT clinical implementation.