Evidence map›Paper›PMID 30531423›Full record

ArticleClinical orthopaedics and related research2019

Is There a Force Target That Predicts Early Patient-reported Outcomes After Kinematically Aligned TKA?

Trevor J Shelton, Stephen M Howell, Maury L Hull

Open access · greenAbstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
6.6field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 39 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Restricted kinematic alignment leads to uncompromised osseointegration of cementless total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022
    Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Alignment in TKA: what has been clear is not anymore!Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019
    Article
  19. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Trevor J SheltonT. J. Shelton, M. L. Hull Department of Orthopaedic Surgery, University of California, Davis, Sacramento, CA, USA S. M. Howell, M. L. Hull Department of Biomedical Engineering, University of California, Davis, Davis, CA, USA M. L. Hull Department of Mechanical Engineering, University of California, Davis, Davis, CA, USA.
Stephen M Howell
Maury L Hull
Zimmer Biomet (United States) · USThink Surgical (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFour mechanical alignment force targets are used to predict early patient-reported outcomes and/or to indicate a balanced TKA. For surgeons who use kinematic alignment, there are no reported force targets. To date the usefulness of these mechanical alignment force targets with kinematic alignment has not been reported nor has a specific force target for kinematic alignment been identified. QUESTIONS/PURPOSES: (1) Does hitting one of four mechanical alignment force targets proposed by Gustke, Jacobs, Meere, and Menghini determine whether a patient with a kinematically aligned TKA had better patient-reported Oxford Knee and WOMAC scores at 6 months? (2) Can a new force target be identified for kinematic alignment that determines whether the patient had a good/excellent Oxford Knee Score of ≥ 34 points (48 best, 0 worst)?

methodsBetween July 2017 and November 2017, we performed 148 consecutive primary TKAs of which all were treated with kinematic alignment using 10 caliper measurements and verification checks. A total of 68 of the 148 (46%) TKAs performed during the study period had intraoperative measurements of medial and lateral tibial compartment forces during passive motion with an instrumented tibial insert and were evaluated in this retrospective study. Because the surgeon and surgical team were blinded from the display showing the compartment forces, there was no attempt to hit a mechanical alignment force target when balancing the knee. The Oxford Knee Score and WOMAC score measured patient-reported outcomes at 6 months postoperatively. For each mechanical alignment force target, a Wilcoxon rank-sum test determined whether patients who hit the target had better outcome scores than those who missed. An area under the curve (AUC) analysis tried to identify a new force target for kinematic alignment at full extension and 10°, 30°, 45°, 60°, 75°, and 90° of flexion that predicted whether patients had a good/excellent Oxford Knee Score, defined as a score of ≥ 34 points.

resultsPatients who hit or missed each of the four mechanical alignment force targets did not have higher or lower Oxford Knee Scores and WOMAC scores at 6 months. Using the Gustke force target as a representative example, the Oxford Knee Score of 41 ± 6 and WOMAC score of 13 ± 11 for the 31 patients who hit the target were not different from the Oxford Knee Score of 39 ± 8 (p = 0.436) and WOMAC score of 17 ± 17 (p = 0.463) for the 37 patients who missed the target. The low observed AUCs (from 0.56 to 0.58) at each of these flexion angles failed to identify a new kinematic alignment force target associated with a good/excellent (≥ 34) Oxford Knee Score.

conclusionsTibial compartment forces comparable to those reported for the native knee and insufficient sensitivity of the Oxford Knee and WOMAC scores might explain why mechanical alignment force targets were not useful and a force target was not identified for kinematic alignment. Intraoperative sensors may allow surgeons to measure forces very precisely in the operating room, but that level of precision is not called for to achieve a good/excellent result after calipered kinematically aligned TKA, and so its use may simply add expense and time but does not improve the results from the patient's viewpoint. LEVEL OF EVIDENCE: Level III, therapeutic study.

Indexed as

AgedArthroplasty, Replacement, KneeFemaleHumansMaleMiddle AgedOsteoarthritis, KneePatient Reported Outcome MeasuresTreatment Outcome

Identifiers

PMID30531423
PMCPMC6494335
OpenAlexW2903691461

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.