Evidence map›Paper›PMID 30530361›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2019

Simultaneous Axial Multifocal Imaging Using a Single Acoustical Transmission: A Practical Implementation.

Asaf Ilovitsh, Tali Ilovitsh, Josquin Foiret, Douglas N Stephens, Katherine W Ferrara

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Asaf Ilovitsh
Tali Ilovitsh
Josquin Foiret
Douglas N Stephens
Katherine W Ferrara

Funding

Specific and high-resolution ultrasound cancer imagingR01CA112356 · NCI · UNIVERSITY OF CALIFORNIA DAVIS · PI FERRARA, KATHERINE W, FOIRET, JOSQUIN · 2005 to 2022
$6.1M
Large aperture and wideband modular ultrasound arrays for the diagnosis of liver cancerR01CA211602 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W, TRAHEY, GREGG E. · 2017 to 2021
$3.3M
Image-guided ultrasound therapy and drug delivery in pancreatic cancerR01CA210553 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W · 2016 to 2020
$3.2M
Ultrasound-guided DNA delivery for regenerative medicineR01EB026094 · NIBIB · CEDARS-SINAI MEDICAL CENTER · PI GAZIT, DAN · 2018 to 2021
$2.8M
Optimized ultrasound-enhanced immunotherapyR01CA199658 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W · 2015 to 2019
$2.5M
NCI NIH HHS R01 CA112356NCI NIH HHS R01 CA199658NCI NIH HHS R01 CA210553NCI NIH HHS R01 CA211602NIBIB NIH HHS R01 EB026094
6 · The paper itself

Abstract

Standard ultrasound imaging techniques rely on sweeping a focused beam across a field of view; however, outside the transmission focal depth, image resolution and contrast are degraded. High-quality deep tissue in vivo imaging requires focusing the emitted field at multiple depths, yielding high-resolution and high-contrast ultrasound images but at the expense of a loss in frame rate. Recent developments in ultrasound technologies have led to user-programmable systems, which enable real-time dynamic control over the phase and apodization of each individual element in the imaging array. In this paper, we present a practical implementation of a method to achieve simultaneous axial multifoci using a single acoustical transmission. Our practical approach relies on the superposition of axial multifoci waveforms in a single transmission. The delay in transmission between different elements is set such that pulses constructively interfere at multiple focal depths. The proposed method achieves lateral resolution similar to successive focusing, but with an enhanced frame rate. The proposed method uses standard dynamic receive beamforming, identical to two-way focusing, and does not require additional postprocessing. Thus, the method can be implemented in real time on programmable ultrasound systems that allow different excitation signals for each element. The proposed method is described analytically and validated by laboratory experiments in phantoms and ex vivo biological samples.

Indexed as

Computer SimulationHumansImage Processing, Computer-AssistedModels, BiologicalPhantoms, ImagingUltrasonography

Identifiers

PMID30530361
PMCPMC6375789

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.