Evidence map›Paper›PMID 30526630›Full record

ArticleJournal of orthopaedic surgery and research2018

Acetabular reinforcement ring with additional hook improves stability in three-dimensional finite element analyses of dysplastic hip arthroplasty.

Koji Totoribe, Etsuo Chosa, Go Yamako, Xin Zhao, Koki Ouchi, Hiroaki Hamada, Gang Deng

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Extended mechanical loads for the analysis of acetabular cages.Biomechanics and modeling in mechanobiology · 2023
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Koji TotoribeDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
Etsuo ChosaDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
Go YamakoDepartment of Mechanical Design Systems, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibana-dai-Nishi, Miyazaki, 889-2192, Japan. g.yamako@cc.miyazaki-u.ac.jp.
Xin ZhaoDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
Koki OuchiDepartment of Mechanical Design Systems, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibana-dai-Nishi, Miyazaki, 889-2192, Japan.
Hiroaki HamadaDepartment of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
Gang DengDepartment of Mechanical Design Systems, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibana-dai-Nishi, Miyazaki, 889-2192, Japan.
University of Miyazaki · JP

Funding

Japan Society for the Promotion of Science 17K01362
6 · The paper itself

Abstract

backgroundThe stability of acetabulum reconstructions using reinforcement rings and hooks is important for successful replacement surgery. The objective of this study was to biomechanically determine the effects of the hook on stress and the related micromotions of the acetabular reinforcement ring during the immediate postoperative period.

methodsAcetabular reinforcement ring models were developed using a nonlinear, three-dimensional, finite element method. Using a pre-prepared template, we constructed without-hook and bone graft models of varying volumes and material properties.

resultsThe stress on the inferior margin of the acetabulum was higher in the with-hook model than in the without-hook model, especially with increased bone graft volumes, and the stiffness of the bone graft material was decreased. Relative micromotions in the without-hook model were higher than in the with-hook models. The highest relative micromotion was observed in the model with increased bone graft volume and lower stiffness of bone graft material.

conclusionsIn biomechanical analyses, the hook effectively dispersed stress and improved the initial fixation strength of the acetabular reinforcement ring.

Indexed as

Finite Element AnalysisSurgical InstrumentsAcetabulumArthroplasty, Replacement, HipHip ProsthesisHumansImaging, Three-DimensionalProsthesis DesignAcetabular reinforcement ringFinite element methodPrimary implant stabilityTotal hip arthroplasty

Identifiers

PMID30526630
PMCPMC6286562
OpenAlexW2903678606

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.