Evidence map›Paper›PMID 30526627›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2018

Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5 T.

Muhummad Sohaib Nazir, Radhouene Neji, Peter Speier, Fiona Reid, Daniel Stäb, Michaela Schmidt, Christoph Forman, Reza Razavi, Sven Plein, Tevfik F Ismail and 2 more

Open access · goldAbstract readVideo-Audio Media
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 1 pooled it
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 1 synthesis or guideline pooled it, 48 citations in OpenAlex.

  1. Society for cardiovascular magnetic resonance expert consensus statement on quantitative myocardial perfusion cardiovascular magnetic resonance imaging.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Guideline
  2. Multiparametric exercise stress cardiovascular magnetic resonance in the diagnosis of coronary artery disease: the EMPIRE trial.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2021
    Trial
  3. Article
  4. Article
  5. Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025
    Article
  6. Review
  7. Clinical utility of a rapid two-dimensional balanced steady-state free precession sequence with deep learning reconstruction.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Cardiac MR: From Theory to Practice.Frontiers in cardiovascular medicine · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 5 institutions in 3 countries.

Muhummad Sohaib NazirSchool of Biomedical Engineering and Imaging Sciences, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SW1 7EH, UK. sohaib.nazir@gmail.com.ORCID 0000-0003-2749-1033
Radhouene NejiSchool of Biomedical Engineering and Imaging Sciences, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SW1 7EH, UK.
Peter SpeierSiemens Healthcare, Erlangen, Germany.
Fiona ReidDivision of Health and Social Care Research, King's College London, London, UK.
Daniel StäbSiemens Healthcare Pty Ltd, Melbourne, Australia.
Michaela SchmidtSiemens Healthcare, Erlangen, Germany.
Christoph FormanSiemens Healthcare, Erlangen, Germany.
Reza RazaviSchool of Biomedical Engineering and Imaging Sciences, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SW1 7EH, UK.
Sven PleinSchool of Biomedical Engineering and Imaging Sciences, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SW1 7EH, UK.
Tevfik F IsmailSchool of Biomedical Engineering and Imaging Sciences, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SW1 7EH, UK.
Amedeo ChiribiriSchool of Biomedical Engineering and Imaging Sciences, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SW1 7EH, UK.
Sébastien RoujolSchool of Biomedical Engineering and Imaging Sciences, King's College London, 3rd Floor Lambeth Wing, St Thomas' Hospital, Westminster Bridge Road, London, SW1 7EH, UK.
St Thomas' Hospital · GBSiemens Healthineers (Germany) · DEKing's College London · GBSiemens (Australia) · AUUniversity of Leeds · GB

Funding

British Heart Foundation CH/16/2/32089British Heart Foundation PG/13/97/30487Medical Research Council MR/P01979X/1Wellcome Trust WT203148/Z/16/Z
6 · The paper itself

Abstract

backgroundSimultaneous-Multi-Slice (SMS) perfusion imaging has the potential to acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial resolution. To maximise signal-to-noise ratio (SNR), SMS can be combined with a balanced steady state free precession (bSSFP) readout. Furthermore, application of gradient-controlled local Larmor adjustment (GC-LOLA) can ensure robustness against off-resonance artifacts and SNR loss can be mitigated by applying iterative reconstruction with spatial and temporal regularisation. The objective of this study was to compare cardiovascular magnetic resonance (CMR) myocardial perfusion imaging using SMS bSSFP imaging with GC-LOLA and iterative reconstruction to 3 slice bSSFP.

methodsTwo contrast-enhanced rest perfusion sequences were acquired in random order in 8 patients: 6-slice SMS bSSFP and 3 slice bSSFP. All images were reconstructed with TGRAPPA. SMS images were also reconstructed using a non-linear iterative reconstruction with L1 regularisation in wavelet space (SMS-iter) with 7 different combinations for spatial (λ

resultsAmong all SMS-iter reconstructions, SMS-iter 6 (λ

conclusionsSMS bSSFP with GC-LOLA and iterative reconstruction improved image quality compared to a 3 slice bSSFP with doubled spatial coverage and preserved in-plane spatial resolution. Future evaluation in patients with coronary artery disease is warranted.

Indexed as

AdultAgedCardiomyopathiesFeasibility StudiesFemaleHumansImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineMaleMiddle AgedMyocardial Perfusion ImagingPredictive Value of TestsProspective StudiesReproducibility of ResultsCardiovascular magnetic resonanceImage accelerationIterative reconstructionMyocardial perfusion imagingSimultaneous multi-slice

Identifiers

PMID30526627
PMCPMC6287353
OpenAlexW2905444076

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.