Evidence map›Paper›PMID 30526626›Full record

ArticleRadiation oncology (London, England)2018

Surface scanning for 3D dose calculation in intraoperative electron radiation therapy.

Verónica García-Vázquez, Begoña Sesé-Lucio, Felipe A Calvo, Juan J Vaquero, Manuel Desco, Javier Pascau

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Evaluation of optical 3D scanning system for radiotherapy use.Journal of medical radiation sciences · 2022
    Article
  5. Three-dimensional photography for intraoperative morphometric analysis in metopic craniosynostosis surgery.International journal of computer assisted radiology and surgery · 2021
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Verónica García-VázquezInstituto de Investigación Sanitaria Gregorio Marañón. Calle Doctor Esquerdo, 46, 28007, Madrid, Spain. vgarcia@hggm.es.ORCID http://orcid.org/0000-0002-8140-3527
Begoña Sesé-LucioInstituto de Investigación Sanitaria Gregorio Marañón. Calle Doctor Esquerdo, 46, 28007, Madrid, Spain.
Felipe A CalvoInstituto de Investigación Sanitaria Gregorio Marañón. Calle Doctor Esquerdo, 46, 28007, Madrid, Spain.
Juan J VaqueroInstituto de Investigación Sanitaria Gregorio Marañón. Calle Doctor Esquerdo, 46, 28007, Madrid, Spain.
Manuel DescoInstituto de Investigación Sanitaria Gregorio Marañón. Calle Doctor Esquerdo, 46, 28007, Madrid, Spain.
Javier PascauInstituto de Investigación Sanitaria Gregorio Marañón. Calle Doctor Esquerdo, 46, 28007, Madrid, Spain.

Funding

ENDORPHINS: TOLERANCE AND DEPENDENCER01DA002013 · NIDA · NEW YORK UNIVERSITY · PI MUSACCHIO, JOSE M · 1986 to 1988
–
Comunidad de Madrid TOPUS-CM S2013/MIT-3024Ministerio de Economía y Competitividad TEC2013-48251-C2-1-RMinisterio de Economía y Competitividad, Instituto de Salud Carlos III and European Regional Development Fund (FEDER) Funds from the European Commission, "A way of making Europe" DTS14/00192Ministerio de Economía y Competitividad, Instituto de Salud Carlos III and European Regional Development Fund (FEDER) Funds from the European Commission, "A way of making Europe" PI15/02121
6 · The paper itself

Abstract

backgroundDose calculations in intraoperative electron radiation therapy (IOERT) rely on the conventional assumption of water-equivalent tissues at the applicator end, which defines a flat irradiation surface. However, the shape of the irradiation surface modifies the dose distribution. Our study explores, for the first time, the use of surface scanning methods for three-dimensional dose calculation of IOERT.

methodsTwo different three-dimensional scanning technologies were evaluated in a simulated IOERT scenario: a tracked conoscopic holography sensor (ConoProbe) and a structured-light three-dimensional scanner (Artec). Dose distributions obtained from computed tomography studies of the surgical field (gold standard) were compared with those calculated under the conventional assumption or from pseudo-computed tomography studies based on surfaces.

resultsIn the simulated IOERT scenario, the conventional assumption led to an average gamma pass rate of 39.9% for dose values greater than 10% (two configurations, with and without blood in the surgical field). Results improved when considering surfaces in the dose calculation (88.5% for ConoProbe and 92.9% for Artec).

conclusionsMore accurate three-dimensional dose distributions were obtained when considering surfaces in the dose calculation of the simulated surgical field. The structured-light three-dimensional scanner provided the best results in terms of dose distributions. The findings obtained in this specific experimental setup warrant further research on surface scanning in the IOERT context owing to the clinical interest of improving the documentation of the actual IOERT scenario.

Indexed as

Radiotherapy DosageElectronsHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalRadiosurgeryRadiotherapy Planning, Computer-AssistedConoscopic holographyDose distributionIntraoperative radiotherapyIOERTStructured-light 3D scannerSurface scanning

Identifiers

PMID30526626
PMCPMC6286593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.