Evidence map›Paper›PMID 30526178›Full record

ArticleActa orthopaedica2019

Suggestion for new 4.4 mm pubo-femoral distance cut-off value for hip instability in lateral position during DDH screening.

Hans-Christen Husum, Michel B Hellfritzsch, Nina Hardgrib, Bjarne Møller-Madsen, Ole Rahbek

Open access · goldAbstract read
In one paragraph

Article in Acta orthopaedica, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Observational
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Hans-Christen Husuma Department of Children's Orthopaedics , Aarhus University Hospital , Aarhus.
Michel B Hellfritzschb Department of Radiology , Aarhus University Hospital , Aarhus.
Nina Hardgribc Department of Paediatrics , Aarhus University Hospital , Aarhus , Denmark.
Bjarne Møller-Madsena Department of Children's Orthopaedics , Aarhus University Hospital , Aarhus.
Ole Rahbeka Department of Children's Orthopaedics , Aarhus University Hospital , Aarhus.
Aarhus University Hospital · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose - Current selective screening algorithms for developmental dysplasia of the hip (DDH) are insufficient. Universal screening programs have been proposed but so far have been deemed too expensive and time consuming. The pubo-femoral distance may solve this problem as a quick, low-cost, highly sensitive, and specific sonographic measurement for DDH, but this has only been validated in the supine position. Therefore we validated pubo-femoral distance (PFD) in the lateral position as an indicator for instability of the hip. Methods - All participants had undergone ultrasonographic diagnostics using the modified Graf technique. In addition, PFD measurements in lateral position were performed. Results were compared between 25 infants who had been treated for DDH because of dysplastic appearance on ultrasound combined with clinical instability and a control group consisting of 100 untreated infants screened for DDH. Sensitivity, specificity, and cut-off points were determined using Receiver operating characteristics (ROC) analysis. Results - We found a mean PFD of 6.8 mm (6.2-7.4) in the treated group with a control group PFD of 3.4 mm (3.3-3.6) (p < 0.005). A PFD value above a threshold of 4.4 mm yielded a sensitivity of 100% and a specificity of 93% for detecting unstable DDH. Interpretation - PFD measured in lateral position was statistically significantly increased in hips of children treated for DDH with Denis Browne hip brace compared with healthy children with unaffected stable hips. Furthermore, the PFD measurement had a high level of sensitivity and specificity at a cut-off value of 4.4 mm. A cut-off value of 6.00 mm has previously been reported as the gold standard in supine position. We suggest that 4.4 mm is used in lateral position.

Indexed as

Hip Dislocation, CongenitalBody Weights and MeasuresDenmarkFemaleFemurHumansInfantJoint InstabilityMalePatient PositioningPubic BoneReproducibility of ResultsSensitivity and SpecificityUltrasonography

Identifiers

PMID30526178
PMCPMC6366463
OpenAlexW2904444277

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.