Monte Carlo study on optimal breast voxel resolution for dosimetry estimates in digital breast tomosynthesis.

Christian Fedon, Carolina Rabin, Marco Caballo, Oliver Diaz, Eloy García, Alejandro Rodríguez-Ruiz, Gabriel A González-Sprinberg, Ioannis Sechopoulos

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Finite element model of mechanical imaging of the breast.Journal of medical imaging (Bellingham, Wash.) · 2022
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Christian FedonDepartment of Radiology and Nuclear Medicine, Radboud University Medical Centre, Geert Grooteplein 10, 6525 GA, Nijmgen, The Netherlands.ORCID 0000-0002-5998-453X
Carolina RabinInstituto de Física, Facultad de Ciencias, Universidad de la República, Iguá 4225, Montevideo 11600, Uruguay.
Marco CaballoDepartment of Radiology and Nuclear Medicine, Radboud University Medical Centre, Geert Grooteplein 10, 6525 GA, Nijmgen, The Netherlands.ORCID 0000-0002-3700-2785
Oliver DiazComputer vision and robotics institute, University of Girona, Campus Montilivi, 17071 Girona, Spain.
Eloy GarcíaRobotics Group, University of León, MIC, 24071 León, Spain.ORCID 0000-0002-0587-1919
Alejandro Rodríguez-RuizDepartment of Radiology and Nuclear Medicine, Radboud University Medical Centre, Geert Grooteplein 10, 6525 GA, Nijmgen, The Netherlands.ORCID 0000-0002-7554-5561
Gabriel A González-SprinbergInstituto de Física, Facultad de Ciencias, Universidad de la República, Iguá 4225, Montevideo 11600, Uruguay.
Ioannis SechopoulosDepartment of Radiology and Nuclear Medicine, Radboud University Medical Centre, Geert Grooteplein 10, 6525 GA, Nijmgen, The Netherlands.

Funding

Image Quality Improvement and Breast Compression Reduction in Breast TomosynthesiR01CA163746 · NCI · RADBOUD UNIVERSITY NIJMEGEN MED CTR · PI SECHOPOULOS, IOANNIS · 2012 to 2015
$1.2M
Image Quality Improvement and Performance Assessment of Dedicated Breast CTR01CA181171 · NCI · STICHTING RADBOUD UNIVERSITAIR MEDISCH CENTRUM I.O. · PI SECHOPOULOS, IOANNIS · 2015 to 2020
$1.1M
NCI NIH HHS R01 CA163746NCI NIH HHS R01 CA181171
6 · The paper itself

Abstract

Digital breast tomosynthesis (DBT) is currently used as an adjunct technique to digital mammography (DM) for breast cancer imaging. Being a quasi-3D image, DBT is capable of providing depth information on the internal breast glandular tissue distribution, which may be enough to obtain an accurate patient-specific radiation dose estimate. However, for this, information regarding the location of the glandular tissue, especially in the vertical direction (i.e. x-ray source to detector), is needed. Therefore, a dedicated reconstruction algorithm designed to localize the amount of glandular tissue, rather than for optimal diagnostic value, could be desirable. Such a reconstruction algorithm, or, alternatively, a reconstructed DBT image classification algorithm, could benefit from the use of larger voxels, rather than the small sizes typically used for the diagnostic task. In addition, the Monte Carlo (MC) based dose estimates would be accelerated by the representation of the breast tissue with fewer and larger voxels. Therefore, in this study we investigate the optimal DBT reconstructed voxel size that allows accurate dose evaluations (i.e. within 5%) using a validated Geant4-based MC code. For this, sixty patient-based breast models, previously acquired using dedicated breast computed tomography (BCT) images, were deformed to reproduce the breast during compression under a given DBT scenario. Two re-binning approaches were applied to the compressed phantoms, leading to isotropic and anisotropic voxels of different volumes. MC DBT simulations were performed reproducing the acquisition geometry of a SIEMENS Mammomat Inspiration system. Results show that isotropic cubic voxels of 2.73 mm size provide a dose estimate accurate to within 5% for 51/60 patients, while a comparable accuracy is obtained with anisotropic voxels of dimension 5.46  ×  5.46  ×  2.73 mm

Indexed as

MammographyMonte Carlo MethodAlgorithmsBreastFemaleHumansImaging, Three-DimensionalPhantoms, ImagingRadiometry

Identifiers

PMID30524034
PMCPMC6467520

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.