Observational studyJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2019
Single-brand dual-chamber discriminators to prevent inappropriate shocks in patients implanted with prophylactic implantable cardioverter defibrillators: a propensity-weighted comparison of single- and dual-chamber devices.
Observational study in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 11 citations in OpenAlex.
- ACC/AHA/ASE/HFSA/HRS/SCAI/SCCT/SCMR 2025 Appropriate Use Criteria for Implantable Cardioverter-Defibrillators, Cardiac Resynchronization Therapy, and Pacing.Journal of the American College of Cardiology · 2025Guideline
- Comparison of Single-Coil Versus Dual-Coil Implantable Cardioverter Defibrillator Devices: A Systematic Review and Meta-Analysis of Efficacy and Extraction-Related Outcomes.Clinical cardiology · 2025Pooled it
- Predictors of Atrial High-Rate Episodes and Inappropriate Device Therapy in Implantable Cardioverter Defibrillators.Pacing and clinical electrophysiology : PACE · 2026Article
- Next-generation ICDs: Individualised Selection for Improved Cardiac Outcomes.Arrhythmia & electrophysiology review · 2026Review
- Implantable Defibrillators: Which Is the Best Device for Each Patient?Journal of cardiovascular electrophysiology · 2025Review
- Head-to-Head Comparison of Single- Versus Dual-Chamber ICD Discriminators for Tachyarrhythmia Detection: A Single-Manufacturer, Remote Monitoring-Based Bicentric Study.Journal of clinical medicine · 2025Article
- Arrhythmia Detection in Atrioventricular, Single-Lead, Floating Atrial Dipole ICD Systems Compared with Conventional Single- and Dual-Chamber Defibrillators.Journal of cardiovascular development and disease · 2024Article
- Successful Identification of and Discrimination Between Atrial and Ventricular Arrhythmia with the Aid of Pacing and Defibrillator Devices.Arrhythmia & electrophysiology review · 2021Review
- Long-Term Outcomes Among a Nationwide Cohort of Patients Using an Implantable Cardioverter-Defibrillator: UMBRELLA Study Final Results.Journal of the American Heart Association · 2021Observational
- Over- and undersensing-pitfalls of arrhythmia detection with implantable devices and wearables.Herzschrittmachertherapie & Elektrophysiologie · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 10 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeComparisons of the efficacy of dual- vs. single-chamber implantable cardioverter defibrillators (ICDs) in preventing inappropriate shocks have had contradictory results. We investigated whether dual-chamber devices have a lower risk of inappropriate shocks and the specific role of supraventricular tachycardia (SVT) discriminators.
methodsAll heart failure (HF) patients without an indication for pacing and implanted with a prophylactic ICD were recruited from the nationwide multicenter UMBRELLA registry. Arrhythmic events were collected by remote monitoring and reviewed by a committee of experts.
resultsAmong 782 patients, single-chamber ICDs were implanted in 537 (68.7%) and dual-chamber devices in 245 (31.3%). During a mean follow-up of 52.2 ± 24.5 months, 109 inappropriate shocks were delivered in 49 patients (6.2%). In the propensity-score-matched analysis, dual-chamber ICDs were related to lower rates of inappropriate shocks as compared to single-chamber devices (0.9% vs. 11.8%, p = < 0.001, log-rank test). In multivariable Cox proportional analysis, independent predictors of inappropriate shock were history of atrial fibrillation (hazard ratio (HR) = 2.78, CI 1.37-5.64, p = 0.004), chronic kidney disease (HR = 6.15, CI 2.82-13.53, p < 0.001), and non-ischemic cardiomyopathy (HR = 2.84, CI 1.54-5.23, p = 0.001). Among ICD settings, PR logic was the only discriminator independently related to a reduced risk of inappropriate shocks (HR = 0.18, CI 0.06-0.48, p = 0.001), along with an SVT limit enabled over 200 bpm (HR = 0.24, CI 0.11-0.51, p < 0.001).
conclusionsIn this nationwide cohort of primary prevention ICD-only patients, dual-chamber devices were related to lower risk of inappropriate shocks compared to single-chamber ICDs. Besides, PR logic and SVT limit > 200 bpm emerged as protective factors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials