Evidence map›Paper›PMID 30521691›Full record

SynthesisThe Cochrane database of systematic reviews2018

Computer-assisted diagnosis techniques (dermoscopy and spectroscopy-based) for diagnosing skin cancer in adults.

Lavinia Ferrante di Ruffano, Yemisi Takwoingi, Jacqueline Dinnes, Naomi Chuchu, Susan E Bayliss, Clare Davenport, Rubeta N Matin, Kathie Godfrey, Colette O'Sullivan, Abha Gulati and 8 more

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 67 papers, 14 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
67citing papers in PubMed, 14 pooled it
5.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

67 citing papers in PubMed, 14 syntheses or guidelines pooled it, 141 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Pooled it
  7. Optical coherence tomography for diagnosing skin cancer in adults.The Cochrane database of systematic reviews · 2018
    Pooled it
  8. Pooled it
  9. Pooled it
  10. Pooled it
  11. Teledermatology for diagnosing skin cancer in adults.The Cochrane database of systematic reviews · 2018
    Pooled it
  12. Pooled it
  13. High-frequency ultrasound for diagnosing skin cancer in adults.The Cochrane database of systematic reviews · 2018
    Pooled it
  14. Reflectance confocal microscopy for diagnosing cutaneous melanoma in adults.The Cochrane database of systematic reviews · 2018
    Pooled it
  15. Active and sham transcranial direct current stimulation (tDCS) improved quality of life in female patients with fibromyalgia.Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation · 2022
    Trial
  16. Trial
  17. Review
  18. Review
  19. Article
  20. Article

7 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors at 11 institutions in 1 country.

Lavinia Ferrante di RuffanoInstitute of Applied Health Research, University of Birmingham, Edgbaston Campus, Birmingham, UK, B15 2TT.
Yemisi Takwoingi
Jacqueline Dinnes
Naomi Chuchu
Susan E Bayliss
Clare Davenport
Rubeta N Matin
Kathie Godfrey
Colette O'Sullivan
Abha Gulati
Sue Ann Chan
Alana Durack
Susan O'Connell
Matthew D Gardiner
Jeffrey Bamber
Jonathan J Deeks
Hywel C Williams
Cochrane Skin Cancer Diagnostic Test Accuracy Group
University of Birmingham · GBNIHR Birmingham Biomedical Research Centre · GBUniversity of Nottingham · GBBarts Health NHS Trust · GBBirmingham City Hospital · GBCambridge University Hospitals NHS Foundation Trust · GBChurchill Hospital · GBCochrane · GBInstitute of Cancer Research · GBUniversity Hospital of Wales · GBUniversity of Oxford · GB

Funding

Cancer Research UK 16464Department of Health 13/89/15
6 · The paper itself

Abstract

backgroundEarly accurate detection of all skin cancer types is essential to guide appropriate management and to improve morbidity and survival. Melanoma and cutaneous squamous cell carcinoma (cSCC) are high-risk skin cancers which have the potential to metastasise and ultimately lead to death, whereas basal cell carcinoma (BCC) is usually localised with potential to infiltrate and damage surrounding tissue. Anxiety around missing early curable cases needs to be balanced against inappropriate referral and unnecessary excision of benign lesions. Computer-assisted diagnosis (CAD) systems use artificial intelligence to analyse lesion data and arrive at a diagnosis of skin cancer. When used in unreferred settings ('primary care'), CAD may assist general practitioners (GPs) or other clinicians to more appropriately triage high-risk lesions to secondary care. Used alongside clinical and dermoscopic suspicion of malignancy, CAD may reduce unnecessary excisions without missing melanoma cases.

objectivesTo determine the accuracy of CAD systems for diagnosing cutaneous invasive melanoma and atypical intraepidermal melanocytic variants, BCC or cSCC in adults, and to compare its accuracy with that of dermoscopy. SEARCH

methodsWe undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists and published systematic review articles. SELECTION CRITERIA: Studies of any design that evaluated CAD alone, or in comparison with dermoscopy, in adults with lesions suspicious for melanoma or BCC or cSCC, and compared with a reference standard of either histological confirmation or clinical follow-up. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). We contacted authors of included studies where information related to the target condition or diagnostic threshold were missing. We estimated summary sensitivities and specificities separately by type of CAD system, using the bivariate hierarchical model. We compared CAD with dermoscopy using (a) all available CAD data (indirect comparisons), and (b) studies providing paired data for both tests (direct comparisons). We tested the contribution of human decision-making to the accuracy of CAD diagnoses in a sensitivity analysis by removing studies that gave CAD results to clinicians to guide diagnostic decision-making. MAIN

resultsWe included 42 studies, 24 evaluating digital dermoscopy-based CAD systems (Derm-CAD) in 23 study cohorts with 9602 lesions (1220 melanomas, at least 83 BCCs, 9 cSCCs), providing 32 datasets for Derm-CAD and seven for dermoscopy. Eighteen studies evaluated spectroscopy-based CAD (Spectro-CAD) in 16 study cohorts with 6336 lesions (934 melanomas, 163 BCC, 49 cSCCs), providing 32 datasets for Spectro-CAD and six for dermoscopy. These consisted of 15 studies using multispectral imaging (MSI), two studies using electrical impedance spectroscopy (EIS) and one study using diffuse-reflectance spectroscopy. Studies were incompletely reported and at unclear to high risk of bias across all domains. Included studies inadequately address the review question, due to an abundance of low-quality studies, poor reporting, and recruitment of highly selected groups of participants.Across all CAD systems, we found considerable variation in the hardware and software technologies used, the types of classification algorithm employed, methods used to train the algorithms, and which lesion morphological features were extracted and analysed across all CAD systems, and even between studies evaluating CAD systems. Meta-analysis found CAD systems had high sensitivity for correct identification of cutaneous invasive melanoma and atypical intraepidermal melanocytic variants in highly selected populations, but with low and very variable specificity, particularly for Spectro-CAD systems. Pooled data from 22 studies estimated the sensitivity of Derm-CAD for the detection of melanoma as 90.1% (95% confidence interval (CI) 84.0% to 94.0%) and specificity as 74.3% (95% CI 63.6% to 82.7%). Pooled data from eight studies estimated the sensitivity of multispectral imaging CAD (MSI-CAD) as 92.9% (95% CI 83.7% to 97.1%) and specificity as 43.6% (95% CI 24.8% to 64.5%). When applied to a hypothetical population of 1000 lesions at the mean observed melanoma prevalence of 20%, Derm-CAD would miss 20 melanomas and would lead to 206 false-positive results for melanoma. MSI-CAD would miss 14 melanomas and would lead to 451 false diagnoses for melanoma. Preliminary findings suggest CAD systems are at least as sensitive as assessment of dermoscopic images for the diagnosis of invasive melanoma and atypical intraepidermal melanocytic variants. We are unable to make summary statements about the use of CAD in unreferred populations, or its accuracy in detecting keratinocyte cancers, or its use in any setting as a diagnostic aid, because of the paucity of studies. AUTHORS'

conclusionsIn highly selected patient populations all CAD types demonstrate high sensitivity, and could prove useful as a back-up for specialist diagnosis to assist in minimising the risk of missing melanomas. However, the evidence base is currently too poor to understand whether CAD system outputs translate to different clinical decision-making in practice. Insufficient data are available on the use of CAD in community settings, or for the detection of keratinocyte cancers. The evidence base for individual systems is too limited to draw conclusions on which might be preferred for practice. Prospective comparative studies are required that evaluate the use of already evaluated CAD systems as diagnostic aids, by comparison to face-to-face dermoscopy, and in participant populations that are representative of those in which the test would be used in practice.

Indexed as

Electric ImpedanceAdultAlgorithmsBasal Cell CarcinomaCarcinoma, Squamous CellClinical Decision-MakingCutaneous Malignant MelanomaDermoscopyDiagnosis, Computer-AssistedFalse Positive ReactionsHumansMelanomaSensitivity and SpecificitySkin Neoplasms

Identifiers

PMID30521691
PMCPMC6517147
OpenAlexW2889012277

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.