Evidence map›Paper›PMID 30521090›Full record

ArticleClinical anatomy (New York, N.Y.)2019

Computerized anatomy of the distal radius and its relevance to volar plating, research, and teaching.

Dominic Gehweiler, Teun Teunis, Viktor Varjas, Dirk Kerstan, Boyko Gueorguiev, Lukas Kamer, Hansrudi Noser

Open access · hybridAbstract read
In one paragraph

Article in Clinical anatomy (New York, N.Y.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Dominic GehweilerAO Research Institute Davos, Davos, Switzerland.
Teun TeunisPlastic Surgery Department, University Medical Center Utrecht, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0001-5660-0695
Viktor VarjasAO Research Institute Davos, Davos, Switzerland.
Dirk KerstanDePuy Synthes, Zuchwil, Switzerland.
Boyko GueorguievAO Research Institute Davos, Davos, Switzerland.
Lukas KamerAO Research Institute Davos, Davos, Switzerland.
Hansrudi NoserAO Research Institute Davos, Davos, Switzerland.
AO Foundation · CHSynthena (Switzerland) · CHUtrecht University · NL

Funding

DePuy Synthes, Zuchwil, Switzerland
6 · The paper itself

Abstract

Distal radius fractures are common and fracture patterns and fixation can be complex. Computerized anatomy evaluation (CAE) might offer non-invasive and enhanced anatomy assessment that might help with implant selection and placement and screw length determination. Our goal was to test the accuracy of two CAE methods for anatomical volar plate positioning and screw lengths measurement of the distal radius. We included 56 high-resolution peripheral quantitative computed tomography scans of intact, human distal radii. Plates were placed manually onto 3D printed models (method 1), which was compared with automated computerized plate placement onto the 3D computer models (method 2). Subsequently, screw lengths were determined digitally for both methods. Screw lengths evaluations were compared via Bland-Altman plots. Both CAE methods resulted in identical volar plate selection and in anatomical plate positioning. For screw length the concordance correlation coefficient was ≥0.91, the location shift ≤0.22 mm, and the scale shift ≤0.16. The differences were smaller than ±1 mm in all samples. Both CAE methods allow for comparable plate positioning and subsequent screw length measurement in distal radius volar plating. Both can be used as a non-invasive teaching environment for volar plate fixation. Method 2 even offers fully computerized assessments. Future studies could compare our models to other anatomical areas, post-operative volar plate positioning, and model performance in actual distal radius fracture instead of intact radii. Clin. Anat. 32:361-368, 2019. © 2018 The Authors. Clinical Anatomy published by Wiley Periodicals, Inc. on behalf of American Association of Clinical Anatomists.

Indexed as

Bone PlatesBone ScrewsCadaverFracture Fixation, InternalHumansImaging, Three-DimensionalOrthopedic ProceduresRadiusRadius FracturesTomography, X-Ray Computedanatomyradiustomography

Identifiers

PMID30521090
PMCPMC7379250
OpenAlexW2905128925

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.