Evidence map›Paper›PMID 30519959›Full record

ArticleAnalytical and bioanalytical chemistry2019

A validated workflow for drug detection in oral fluid by non-targeted liquid chromatography-tandem mass spectrometry.

Vera Reinstadler, Stefan Lierheimer, Michael Boettcher, Herbert Oberacher

Open access · hybridAbstract readValidation Study
In one paragraph

Article in Analytical and bioanalytical chemistry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. A critical review of workplace drug testing methods for old and new psychoactive substances: Gaps, advances, and perspectives.Saudi pharmaceutical journal : SPJ : the official publication of the Saudi Pharmaceutical Society · 2024
    Article
  3. Interpol review of toxicology 2019-2022.Forensic science international. Synergy · 2023
    Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Vera ReinstadlerInstitute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Muellerstr. 44, 6020, Innsbruck, Austria.
Stefan LierheimerMVZ Labor Dessau GmbH, Bauhüttenstr. 6, 06847, Dessau-Roßlau, Germany.
Michael BoettcherMVZ Labor Dessau GmbH, Bauhüttenstr. 6, 06847, Dessau-Roßlau, Germany.
Herbert OberacherInstitute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Muellerstr. 44, 6020, Innsbruck, Austria. herbert.oberacher@i-med.ac.at.
Städtisches Klinikum Dessau · DEInnsbruck Medical University · ATUniversität Innsbruck · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Oral fluid is recognized as an important specimen for drug testing. Common applications are monitoring in substance abuse treatment programs, therapeutic drug monitoring, pain management, workplace drug testing, clinical toxicology, and driving under the influence of drugs (DRUID). In this study, we demonstrate that non-targeted LC-MS/MS with subsequent compound identification by tandem mass spectral library search is a valuable tool for comprehensive detection and confirmation of drugs in oral fluid samples. The workflow developed involves solid-phase extraction and chromatographic separation on reversed phase materials. Mass spectrometric detection is accomplished on a quadrupole-quadrupole-time-of-flight instrument operated with data-dependent acquisition control. The workflow was optimized for 500 μl of neat oral fluid collected with the Greiner Bio-One saliva collection system. The fitness of the developed method was tested and proven by analyzing blank and spiked samples as well as 59 authentic patient samples. We could demonstrate that compounds with logP values in the range 0.5-5.5 are efficiently detected at low nanograms per milliliter concentrations. The true positive and true negative rates of automated library search were equal or close to 100%. The beauty of the non-targeted LC-MS/MS approach is the ability to detect compounds hardly included in routinely applied targeted assays, and this was demonstrated by detecting the synthetic opioid U-47700 in two patient samples. Graphical abstract ᅟ.

Indexed as

WorkflowBenzamidesChromatography, LiquidHumansIllicit DrugsOpiate Substitution TreatmentOpioid-Related DisordersReference StandardsSalivaSolid Phase ExtractionSubstance Abuse DetectionTandem Mass SpectrometryBenzamidesIllicit DrugsU-47700Liquid chromatography-tandem mass spectrometryNon-targeted analysisOral fluidSalivaSynthetic opioidSystematic toxicological analysis

Identifiers

PMID30519959
PMCPMC6338695
OpenAlexW2903947646

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390