ArticleWorld journal of methodology2018
Assessment of quality control system by sigma metrics and quality goal index ratio: A roadmap towards preparation for NABL.
Article in World journal of methodology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- A 25-year Experience in Quality Assurance: A Methodological Review of Laboratory Quality Control and Quality Assurance in the Tehran Lipid and Glucose Study (TLGS).International journal of endocrinology and metabolism · 2027Review
- Analytical performance evaluation of intelligent quality management of blood gas analyzer.Practical laboratory medicine · 2025Article
- Application of random quality control based on time -series model in ELISA detection of blood donors in Nanjing.Heliyon · 2024Article
- Six SIGMA evaluation of 17 biochemistry parameters using bias calculated from internal quality control and external quality assurance data.Journal of medical biochemistry · 2024Article
- The application of sigma metrics in the laboratory to assess quality control processes in South Africa.African journal of laboratory medicine · 2022Article
- Application of Sigma metrics in the quality control strategies of immunology and protein analytes.Journal of clinical laboratory analysis · 2021Article
- Practical application of Westgard Sigma rules with run size in analytical biochemistry processes in clinical settings.Journal of clinical laboratory analysis · 2021Article
- Analysis of performance of clinical biochemistry laboratory using Sigma metrics and Quality Goal Index.Practical laboratory medicine · 2021Article
- Practical application of Six Sigma management in analytical biochemistry processes in clinical settings.Journal of clinical laboratory analysis · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimTo study sigma metrics and quality goal index ratio (QGI).
methodsThe retrospective study was conducted at the Clinical Biochemistry Laboratory, PGIMS, Rohtak, which recently became a National Accreditation Board for Testing and Calibration of Laboratories accredited lab as per the International Organization for Standardization 15189:2012 and provides service to a > 1700-bed tertiary care hospital. Data of 16 analytes was extracted over a period of one year from January 2017 to December 2017 for calculation of precision, accuracy, sigma metrics, total error, and QGI.
resultsThe average coefficient of variation ranged from 2.12% (albumin) to 5.42% (creatinine) for level 2 internal quality control and 2% (albumin) to 3.62% (high density lipoprotein-cholesterol) for level 3 internal quality control. Average coefficient of variation of all the parameters was below 5%, reflecting very good precision. The sigma metrics for level 2 indicated that 11 (68.5%) of the 16 parameters fall short of meeting Six Sigma quality performance. Of these, five failed to meet minimum sigma quality performance with metrics less than 3, and another six just met minimal acceptable performance with sigma metrics between 3 and 6. For level 3, the data collected indicated eight (50%) of the parameters did not achieve Six Sigma quality performance, out of which three had metrics less than 3, and five had metrics between 3 and 6. QGI ratio indicated that the main problem was inaccuracy in the case of total cholesterol, aspartate transaminase, and alanine transaminase (QGI > 1.2), imprecision in the case of urea (QGI < 0.8), and both imprecision and inaccuracy for glucose.
conclusionOn the basis of sigma metrics and QGI, it may be concluded that the Clinical Biochemistry Laboratory, PGIMS, Rohtak was able to achieve satisfactory results with world class performance for many analytes one year preceding the accreditation by the National Accreditation Board for Testing and Calibration of Laboratories. Aspartate transaminase and alanine transaminase required strict external quality assurance scheme monitoring and modification in quality control procedure as their QGI ratio showed inaccuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.