Evidence map›Paper›PMID 30519539›Full record

ArticleWorld journal of methodology2018

Assessment of quality control system by sigma metrics and quality goal index ratio: A roadmap towards preparation for NABL.

Monica Verma, Kiran Dahiya, Veena Singh Ghalaut, Vasudha Dhupper

Abstract read
In one paragraph

Article in World journal of methodology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Monica VermaDepartment of Biochemistry, Pt. B.D. Sharma, University of Health Sciences, Rohtak 124001, Haryana, India. monisoni26@gmail.com.
Kiran DahiyaDepartment of Biochemistry, Pt. B.D. Sharma, University of Health Sciences, Rohtak 124001, Haryana, India.
Veena Singh GhalautDepartment of Biochemistry, Pt. B.D. Sharma, University of Health Sciences, Rohtak 124001, Haryana, India.
Vasudha DhupperDepartment of Biochemistry, Pt. B.D. Sharma, University of Health Sciences, Rohtak 124001, Haryana, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo study sigma metrics and quality goal index ratio (QGI).

methodsThe retrospective study was conducted at the Clinical Biochemistry Laboratory, PGIMS, Rohtak, which recently became a National Accreditation Board for Testing and Calibration of Laboratories accredited lab as per the International Organization for Standardization 15189:2012 and provides service to a > 1700-bed tertiary care hospital. Data of 16 analytes was extracted over a period of one year from January 2017 to December 2017 for calculation of precision, accuracy, sigma metrics, total error, and QGI.

resultsThe average coefficient of variation ranged from 2.12% (albumin) to 5.42% (creatinine) for level 2 internal quality control and 2% (albumin) to 3.62% (high density lipoprotein-cholesterol) for level 3 internal quality control. Average coefficient of variation of all the parameters was below 5%, reflecting very good precision. The sigma metrics for level 2 indicated that 11 (68.5%) of the 16 parameters fall short of meeting Six Sigma quality performance. Of these, five failed to meet minimum sigma quality performance with metrics less than 3, and another six just met minimal acceptable performance with sigma metrics between 3 and 6. For level 3, the data collected indicated eight (50%) of the parameters did not achieve Six Sigma quality performance, out of which three had metrics less than 3, and five had metrics between 3 and 6. QGI ratio indicated that the main problem was inaccuracy in the case of total cholesterol, aspartate transaminase, and alanine transaminase (QGI > 1.2), imprecision in the case of urea (QGI < 0.8), and both imprecision and inaccuracy for glucose.

conclusionOn the basis of sigma metrics and QGI, it may be concluded that the Clinical Biochemistry Laboratory, PGIMS, Rohtak was able to achieve satisfactory results with world class performance for many analytes one year preceding the accreditation by the National Accreditation Board for Testing and Calibration of Laboratories. Aspartate transaminase and alanine transaminase required strict external quality assurance scheme monitoring and modification in quality control procedure as their QGI ratio showed inaccuracy.

Indexed as

BiasCoefficient of variationImprecisionInaccuracyQuality goal indexSigma

Identifiers

PMID30519539
PMCPMC6275555

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.