Evidence map›Paper›PMID 30518387›Full record

ArticleBiomedical engineering online2018

Uniqueness of local myocardial strain patterns with respect to activation time and contractility of the failing heart: a computational study.

Borut Kirn, John Walmsley, Joost Lumens

Abstract read
In one paragraph

Article in Biomedical engineering online, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Feasibility and potential benefit of pre-procedural CMR imaging in patients with ischaemic cardiomyopathy undergoing cardiac resynchronisation therapy.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Borut KirnDepartment of Physiology, Medical Faculty, University of Ljubljana, Zaloska 4, 1000, Ljubljana, Slovenia. borut.kirn@mf.uni-lj.si.ORCID http://orcid.org/0000-0002-9085-2308
John WalmsleyDepartment of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands.
Joost LumensDepartment of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht, The Netherlands.

Funding

Hartstichting 2015T082Javna Agencija za Raziskovalno Dejavnost RS P3-0019
6 · The paper itself

Abstract

backgroundMyocardial deformation measured by strain is used to detect electro-mechanical abnormalities in cardiac tissue. Estimation of myocardial properties from regional strain patterns when multiple pathologies are present is therefore a promising application of computer modelling. However, if different tissue properties lead to indistinguishable strain patterns ('degeneracy'), the applicability of any such method will be limited. We investigated whether estimation of local activation time (AT) and contractility from myocardial strain patterns is theoretically possible.

methodsFor four different global cardiac pathologies local myocardial strain patterns for 1025 combinations of AT and contractility were simulated with a computational model (CircAdapt). For each strain pattern, a cohort of similar patterns was found within estimated measurement error using the sum of least-squared differences. Cohort members came from (1) the same pathology only, and (2) all four pathologies. Uncertainty was calculated as accuracy and precision of cohort members in parameter space. Connectedness within the cohorts was also studied.

resultsWe found that cohorts drawn from one pathology had parameters with adjacent values although their distribution was neither constant nor symmetrical. In comparison cohorts drawn from four pathologies had disconnected components with drastically different parameter values and accuracy and precision values up to three times higher.

conclusionsGlobal pathology must be known when extracting AT and contractility from strain patterns, otherwise degeneracy occurs causing unacceptable uncertainty in derived parameters.

Indexed as

Models, CardiovascularMyocardial ContractionStress, MechanicalBiomechanical PhenomenaHeart FailureMyocardiumUncertaintyActivation timeCardiac strainComputer simulationContractilityReverse engineeringSystem degeneration

Identifiers

PMID30518387
PMCPMC6280493

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.