Evidence map›Paper›PMID 30514303›Full record

ArticleBiomedical engineering online2018

Adaptive filtering of physiological noises in fNIRS data.

Hoang-Dung Nguyen, So-Hyeon Yoo, M Raheel Bhutta, Keum-Shik Hong

Abstract read
In one paragraph

Article in Biomedical engineering online, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. A Deep-Learning Empowered, Real-Time Processing Platform of fNIRS/DOT for Brain Computer Interfaces and Neurofeedback.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2025
    Article
  5. Article
  6. Article
  7. [A deep transfer learning approach for cross-subject recognition of mental tasks based on functional near-infrared spectroscopy].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hoang-Dung NguyenDepartment of Automation Technology, Can Tho University, Can Tho, 900000, Vietnam.
So-Hyeon YooSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Republic of Korea.
M Raheel BhuttaDepartment of Computer Science and Engineering, Sejong University, Seoul, 05006, Republic of Korea.
Keum-Shik HongSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Republic of Korea. kshong@pusan.ac.kr.ORCID http://orcid.org/0000-0002-8528-4457

Funding

The National Research Foundation (NRF) of Korea under the auspices of the Ministry of Science and ICT, Republic of Korea NRF-2017R1A2A1A17069430The National Research Foundation (NRF) of Korea under the auspices of the Ministry of Science and ICT, Republic of Korea NRF-2017R1A4A1015627
6 · The paper itself

Abstract

The study presents a recursive least-squares estimation method with an exponential forgetting factor for noise removal in functional near-infrared spectroscopy data and extraction of hemodynamic responses (HRs) from the measured data. The HR is modeled as a linear regression form in which the expected HR, the first and second derivatives of the expected HR, a short-separation measurement data, three physiological noises, and the baseline drift are included as components in the regression vector. The proposed method is applied to left-motor-cortex experiments on the right thumb and little finger movements in five healthy male participants. The algorithm is evaluated with respect to its performance improvement in terms of contrast-to-noise ratio in comparison with Kalman filter, low-pass filtering, and independent component method. The experimental results show that the proposed model achieves reductions of 77% and 99% in terms of the number of channels exhibiting higher contrast-to-noise ratios in oxy-hemoglobin and deoxy-hemoglobin, respectively. The approach is robust in obtaining consistent HR data. The proposed method is applied for both offline and online noise removal.

Indexed as

Data AnalysisHemodynamicsSignal-To-Noise RatioSpectroscopy, Near-InfraredAdultBrainHumansLinear ModelsMaleExponential forgettingFunctional near-infrared spectroscopy (fNIRS)Hemodynamic response (HR)Real time estimationRecursive least squares estimation (RLSE)State space model

Identifiers

PMID30514303
PMCPMC6278088

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.