Evidence map›Paper›PMID 30513956›Full record

ArticleSensors (Basel, Switzerland)2018

A Portable Biosensor for 2,4-Dinitrotoluene Vapors.

Marc Prante, Christian Ude, Miriam Große, Lukas Raddatz, Ulrich Krings, Gernot John, Shimshon Belkin, Thomas Scheper

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Migration of Vapor Molecules in Soils.Molecules (Basel, Switzerland) · 2026
    Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Marc PranteInstitute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany. prante@iftc.uni-hannover.de.
Christian UdeInstitute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany. ude@iftc.uni-hannover.de.
Miriam GroßeInstitute of Food Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany. miriam.grosse@lci.uni-hannover.de.
Lukas RaddatzInstitute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany. raddatz@iftc.uni-hannover.de.ORCID 0000-0002-4170-8318
Ulrich KringsInstitute of Food Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany. krings@lci.uni-hannover.de.
Gernot JohnPreSens Precision Sensing GmbH, 93053 Regensburg, Germany. g.john@presens.de.
Shimshon BelkinDepartment of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, The Hebrew University of Jerusalem, 9190401 Jerusalem, Israel. shimshon.belkin@mail.huji.ac.il.ORCID 0000-0001-8283-1673
Thomas ScheperInstitute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany. scheper@iftc.uni-hannover.de.
Leibniz University Hannover · DEHebrew University of Jerusalem · ILPreSens Precision Sensing (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Buried explosive material, e.g., landmines, represent a severe issue for human safety all over the world. Most explosives consist of environmentally hazardous chemicals like 2,4,6-trinitrotoluene (TNT), carcinogenic 2,4-dinitrotoluene (2,4-DNT) and related compounds. Vapors leaking from buried landmines offer a detection marker for landmines, presenting an option to detect landmines without relying on metal detection. 2,4-Dinitrotoluene (DNT), an impurity and byproduct of common TNT synthesis, is a feasible detection marker since it is extremely volatile. We report on the construction of a wireless, handy and cost effective 2,4-dinitrotoluene biosensor combining recombinant bioluminescent bacterial cells and a compact, portable optical detection device. This biosensor could serve as a potential alternative to the current detection technique. The influence of temperature, oxygen and different immobilization procedures on bioluminescence were tested. Oxygen penetration depth in agarose gels was investigated, and showed that aeration with molecular oxygen is necessary to maintain bioluminescence activity at higher cell densities. Bioluminescence was low even at high cell densities and 2,4-DNT concentrations, hence optimization of different prototypes was carried out regarding radiation surface of the gels used for immobilization. These findings were applied to sensor construction, and 50 ppb gaseous 2,4-DNT was successfully detected.

Indexed as

Biosensing TechniquesDinitrobenzenesExplosive AgentsGasesHumansOxygenWireless Technology2,4-dinitrotolueneDinitrobenzenesExplosive AgentsGasesOxygenbiological sensorbioluminescencebiosensorchemical vapor signatureexplosive materiallandmine detection

Identifiers

PMID30513956
PMCPMC6308836
OpenAlexW2902016757

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.