Evidence map›Paper›PMID 30513838›Full record

ArticleSensors (Basel, Switzerland)2018

Cuffless Blood Pressure Estimation Using Pressure Pulse Wave Signals.

Zeng-Ding Liu, Ji-Kui Liu, Bo Wen, Qing-Yun He, Ye Li, Fen Miao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zeng-Ding LiuShenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China. zd.liu@siat.ac.cn.
Ji-Kui LiuShenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China. jk.liu@siat.ac.cn.
Bo WenShenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China. bo.wen@siat.ac.cn.
Qing-Yun HeShenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China. qy.he@siat.ac.cn.
Ye LiShenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China. ye.li@siat.ac.cn.
Fen MiaoShenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China. fen.miao@siat.ac.cn.

Funding

National Natural Science Foundation of China No. 61502472, No. 61771465Science and Technology Planning Project of Guangdong Province No. 2015B010129012, No. 2017B030308007Shenzhen Science and Technology Projects No. JCYJ20170413161515911
6 · The paper itself

Abstract

Pulse transit time (PTT) has received considerable attention for noninvasive cuffless blood pressure measurement. However, this approach is inconvenient to deploy in wearable devices because two sensors are required for collecting two-channel physiological signals, such as electrocardiogram and pulse wave signals. In this study, we investigated the pressure pulse wave (PPW) signals collected from one piezoelectric-induced sensor located at a single site for cuffless blood pressure estimation. Twenty-one features were extracted from PPW that collected from the radial artery, and then a linear regression method was used to develop blood pressure estimation models by using the extracted PPW features. Sixty-five middle-aged and elderly participants were recruited to evaluate the performance of the constructed blood pressure estimation models, with oscillometric technique-based blood pressure as a reference. The experimental results indicated that the mean ± standard deviation errors for the estimated systolic blood pressure and diastolic blood pressure were 0.70 ± 7.78 mmHg and 0.83 ± 5.45 mmHg, which achieved a decrease of 1.33 ± 0.37 mmHg in systolic blood pressure and 1.14 ± 0.20 mmHg in diastolic blood pressure, compared with the conventional PTT-based method. The proposed model also demonstrated a high level of robustness in a maximum 60-day follow-up study. These results indicated that PPW obtained from the piezoelectric sensor has great feasibility for cuffless blood pressure estimation, and could serve as a promising method in home healthcare settings.

Indexed as

cuffless blood pressuremultiparameter fusionpiezoelectric sensorpressure pulse waveformpulse transit time

Identifiers

PMID30513838
PMCPMC6308537

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.