Evidence map›Paper›PMID 30511680›Full record

Trial reportChinese medical journal2018

Safety, Effectiveness, and Manipulability of Peritoneal Dialysis Machines Made in China: A Randomized, Crossover, Multicenter Clinical Study.

Xue-Ying Cao, Ya-Ni He, Jian-Hui Zhou, Shi-Ren Sun, Li-Ning Miao, Wen Chen, Jing-Ai Fang, Ming Wang, Nian-Song Wang, Hong-Li Lin and 11 more

Registry-linked trialAbstract readMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in Chinese medical journal, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02525497 (A Randomized, Multicenter, Crossover Study Comparing the Domestic FM Peritoneal Dialysis Machine With Baxter HOMECHOICE), which is not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02525497 nacompletednot on this map

A Randomized, Multicenter, Crossover Study Comparing the Domestic FM Peritoneal Dialysis Machine With Baxter HOMECHOICE

TypeinterventionalSponsorChinese PLA General HospitalRan2015 to 2017Enrolled360ConditionsKidney Failure,ChronicArmsFM peritoneal dialysis machine, HOMECHOICE peritoneal dialysis machine
3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Qualitative research on the needs status of patients undergoing automated peritoneal dialysis based on behavior change wheel theory.Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2025
    Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

21 authors.

Xue-Ying CaoDepartment of Nephrology, Chinese People's Liberation Army General Hospital, Chinese People's Liberation Army Institute of Nephrology, State Key Laboratory of Kidney Diseases (2011DAV00088), National Clinical Research Center for Kidney Diseases, Beijing 100853, China.
Ya-Ni HeDepartment of Nephrology, Daping Hospital, Army Military Medical University, Chongqing 400042, China.
Jian-Hui ZhouDepartment of Nephrology, Chinese People's Liberation Army General Hospital, Chinese People's Liberation Army Institute of Nephrology, State Key Laboratory of Kidney Diseases (2011DAV00088), National Clinical Research Center for Kidney Diseases, Beijing 100853, China.
Shi-Ren SunDepartment of Nephrology, Xijing Hospital, The Fourth Military Medical University, Xi'an, Shaanxi 710032, China.
Li-Ning MiaoDepartment of Nephrology, Second Hospital of Jilin University, Changchun, Jilin 130041, China.
Wen ChenDepartment of Nephrology, Hainan Provincial Agricultural Reclamation General Hospital, Haikou, Hainan 570311, China.
Jing-Ai FangDepartment of Nephrology, First Affiliated Hospital of Shanxi Medical University, Taiyuan, Shanxi 030001, China.
Ming WangDepartment of Nephrology, Hangzhou First People's Hospital, Hangzhou, Zhejiang 310006, China.
Nian-Song WangDepartment of Nephrology and Rheumatology, Affiliated Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai 200233, China.
Hong-Li LinDepartment of Nephrology, First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China.
Jian LiuDepartment of Nephrology, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830054, China.
Zhao-Hui NiDepartment of Nephrology, Renji Hospital, Shanghai Jiao Tong University, Shanghai 200127, China.
Wen-Hu LiuDepartment of Nephrology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China.
Yu NaDepartment of Nephrology, The 306th Hospital of People's Liberation Army, Beijing 100101, China.
Jiu-Yang ZhaoDepartment of Nephrology, The Second Affiliated Hospital of Dalian Medical University, Dalian Medical University, Dalian, Liaoning 116023, China.
Zhi-Yong GuoDepartment of Nephrology, Changhai Hospital, The Second Military Medical University, Shanghai 200433, China.
Hong-Guang ZhengDepartment of Nephrology, People's Liberation Army General Hospital of Shenyang Military Region, Shenyang, Liaoning 110016, China.
Wei ShiDepartment of Nephrology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong 510080, China.
Geng-Ru JiangDepartment of Nephrology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200092, China.
Guang-Yan CaiDepartment of Nephrology, Chinese People's Liberation Army General Hospital, Chinese People's Liberation Army Institute of Nephrology, State Key Laboratory of Kidney Diseases (2011DAV00088), National Clinical Research Center for Kidney Diseases, Beijing 100853, China.
Xiang-Mei ChenDepartment of Nephrology, Chinese People's Liberation Army General Hospital, Chinese People's Liberation Army Institute of Nephrology, State Key Laboratory of Kidney Diseases (2011DAV00088), National Clinical Research Center for Kidney Diseases, Beijing 100853, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAutomated peritoneal dialysis (APD) can cater to individual needs, provide treatment while asleep, take into account the adequacy of dialysis, and improve the quality of life. Currently, independent research and development of APD machines made in China are more conducive to patients. A randomized, multicenter, crossover study was conducted by comparing an APD machine made in China with an imported machine. The safety, effectiveness, and manipulability of the two machines were compared.

methodsTwo hundred and sixty patients who underwent peritoneal dialysis (PD) on a regular basis in 18 centers between August 2015 and February 2016 were included. The inclusion criteria include age ≥18 years and PD ≥30 days. The exclusion criteria were as follows: hemodialysis; exit site or tunnel infection; and peritonitis ≤30 days. The patients were randomly divided into Group A, who were first treated with a FM machine made in China, then changed to an imported machine; and Group B, who were treated using the reverse sequence. APD treatment was performed with 10 L/10 h and 5 cycles of exchange. After 72 h, the daily peritoneal Kt/V, the accuracy of the injection rate, accuracy of the injection temperature, safety, and manipulability of the machine were assessed. Noninferiority test was conducted between the two groups.

resultsThe daily peritoneal Kt/V in the APD machine made in China and the imported APD machine were 0.17 (0.14, 0.25) and 0.16 (0.13, 0.23), respectively. There was no significant difference between the groups (Z = 0.15, P = 0.703). The lower limit of the daily Kt/V difference between the two groups was 0.0069, which was greater than the noninferiority value of -0.07 in this study. The accuracy of the injection rate and injection temperature was 89.7% and 91.5%, respectively, in the domestic APD machine, which were both slightly better than the accuracy rates of 84.0% and 86.8% in the imported APD machine (89.7% vs. 84.0%, P = 0.2466; 91.5% vs. 86.8%, P = 0.0954). Therefore, the APD machine made in China was not inferior to the imported APD machine. The fuselage of the imported APD machine was space-saving, while the APD machine made in China was superior with respect to body mobility, man-machine dialog operation, alarm control, and patient information recognition.

conclusionsThe FM machine made in China was not inferior to the imported APD machine. In addition, the FM machine made in China had better operability.

trial registrationClinicaltrials.gov, NCT02525497; https://clinicaltrials.gov/ct2/results?cond=&term=NCT02525497&cntry=& state=&city=&dist=.

Indexed as

AdultChinaCross-Over StudiesFemaleHumansMaleMiddle AgedMulticenter Studies as TopicPeritoneal DialysisQuality of LifeTemperatureAutomated Peritoneal DialysisEffectivenessPeritoneal DialysisPeritoneal Dialysis MachineSafety

Identifiers

PMID30511680
PMCPMC6278200

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.