Evidence map›Paper›PMID 30511178›Full record

ArticleEuropean radiology2019

Evaluation of pain reduction and height restoration post vertebral augmentation using a polyether ether ketone (PEEK) polymer implant for the treatment of split (Magerl A2) vertebral fractures: a prospective, long-term, non-randomized study.

Georgios Velonakis, Dimitrios Filippiadis, Stavros Spiliopoulos, Elias Brountzos, Nikolaos Kelekis, Alexis Kelekis

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Georgios Velonakis2nd Department of Radiology, Attikon General University Hospital, National and Kapodistrian University of Athens, Rimini 1, Haidari, 12462, Athens, Greece. giorvelonakis@gmail.com.ORCID http://orcid.org/0000-0002-0050-284X
Dimitrios Filippiadis2nd Department of Radiology, Attikon General University Hospital, National and Kapodistrian University of Athens, Rimini 1, Haidari, 12462, Athens, Greece.
Stavros Spiliopoulos2nd Department of Radiology, Attikon General University Hospital, National and Kapodistrian University of Athens, Rimini 1, Haidari, 12462, Athens, Greece.
Elias Brountzos2nd Department of Radiology, Attikon General University Hospital, National and Kapodistrian University of Athens, Rimini 1, Haidari, 12462, Athens, Greece.
Nikolaos Kelekis2nd Department of Radiology, Attikon General University Hospital, National and Kapodistrian University of Athens, Rimini 1, Haidari, 12462, Athens, Greece.
Alexis Kelekis2nd Department of Radiology, Attikon General University Hospital, National and Kapodistrian University of Athens, Rimini 1, Haidari, 12462, Athens, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe purposes of the study were to evaluate the safety and long-term efficacy of augmented vertebroplasty using a polyether ether ketone (PEEK) implant, for the treatment of lumbar or thoracic vertebral fractures (A2 according to the Magerl's AO classification) and to analyze pain reduction, height restoration, and complications during a 2-year follow-up period.

methodsProspective non-randomized evaluation was performed for 21 painful split vertebral fractures (20 patients, 14 females, 6 males; mean age 72.80 ± 10.991) treated with percutaneous vertebral augmentation using a PEEK device, under fluoroscopic guidance. Pain before the procedure and after 6, 12, and 24 months was evaluated using a numeric visual scale (NVS) questionnaire. Imaging was performed by CT and X-rays. The minimum craniocaudal diameter at the level of the fracture and the maximum craniocaudal diameter at the middle of the fractured vertebra were measured. Statistical analysis was performed to evaluate pain decrease and height restoration.

resultsSuccessful implant positioning was achieved in all cases. No major clinical complications were observed. Comparing the mean pain scores at baseline (8.69 ± 1.138) and the first day after the treatment (1.19 ± 1.424), there was a decrease of 7.50 NVS units (p < 0.001). Minimum and maximum vertebral body heights were increased after the procedure 56.58% and 13.7% respectively (p < 0.001). Both pain relief and height restoration remained statistically significant (p < 0.001) during the follow-up period.

conclusionA2 Magerl thoracic or lumbar fractures could be successfully treated with PEEK implant-assisted vertebral augmentation. Randomized studies with larger sample sizes should be done to confirm the effectiveness of the technique. KEY POINTS: • Vertebral augmentation using a PEEK implant for the treatment of A2 Magerl lumbar or thoracic vertebral fractures seems to be effective both in terms of pain reduction and height restoration. • Effects on pain reduction and height restoration have a long-term duration. • The technique seems to be safe for the treatment of A2 Magerl fractures, without major complications in our study group.

Indexed as

Body HeightAgedBenzophenonesBiocompatible MaterialsFemaleFollow-Up StudiesHumansKetonesLumbar VertebraeMalePainPain ManagementPolyethylene GlycolsPolymersProspective StudiesRadiographyBenzophenonesBiocompatible MaterialsKetonespolyetheretherketonePolyethylene GlycolsPolymersPEEKSpinal fractureVertebroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.