Fast quantitative reconstruction with focusing collimators for liver SPECT.

Martijn M A Dietze, Sandra van der Velden, Marnix G E H Lam, Max A Viergever, Hugo W A M de Jong

Abstract read
In one paragraph

Article in EJNMMI physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Martijn M A DietzeRadiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, Utrecht, GA, Netherlands. M.M.A.Dietze@umcutrecht.nl.ORCID http://orcid.org/0000-0003-1159-3510
Sandra van der VeldenRadiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, Utrecht, GA, Netherlands.
Marnix G E H LamRadiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, Utrecht, GA, Netherlands.
Max A ViergeverImage Sciences Institute, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, Utrecht, GA, Netherlands.
Hugo W A M de JongRadiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, Utrecht, GA, Netherlands.

Funding

Horizon 2020 646734
6 · The paper itself

Abstract

backgroundGeneration of a SPECT scan during procedure may aid in the optimization of treatments as liver radioembolization by offering image-guided dosimetry. This, however, requires both shortened acquisition times and fast quantitative reconstruction. Focusing collimators increase sensitivity and thus may speed up imaging. Monte Carlo-based iterative reconstruction has shown to provide quantitative results for parallel hole collimators but may be slow. The purpose of this work is to develop fast Monte Carlo-based reconstruction for focusing collimators and to evaluate the impact of reconstruction and collimator choice on quantitative accuracy of liver dosimetry by means of simulations.

resultsThe developed fast Monte Carlo simulator was found to accurately generate projections compared to a full Monte Carlo simulation, providing projections in several seconds instead of several days. Monte Carlo-based scatter correction was superior to other scatter correction methods in describing recovered activity and reached similar noise levels as dual-energy window scatter correction. Although truncation artifacts were present in the cone beam collimator (50 cm), the region inside the field of view (FOV) could be reconstructed without loss of accuracy. Provided the object to image is inside the FOV, the focusing collimator with 50 cm focal distance could retrieve the same noise levels as a parallel hole collimator in 68% of the total scanning time, the multifocal collimator in 73% of the time, and the 100-cm focal distance collimator in 84% of the time.

conclusionFocusing collimators combined with Monte Carlo-based reconstruction have the ability to enable quantitative imaging of the FOV in a significantly shorter timeframe. The proposed approach to the forward projector will additionally make it possible to reconstruct within minutes. These are crucial steps in moving toward real-time dosimetry during interventions.

Indexed as

Monte CarloQuantificationRadioembolizationReconstructionSPECT/CT