Evidence map›Paper›PMID 30510796›Full record

ArticleCardiology research and practice2018

A Pilot Study on Parameter Setting of VisiTag™ Module during Pulmonary Vein Isolation.

Yu-Chuan Wang, Bo Huang, Kang Li, Peng-Kang He, Er-Dong Chen, Yu-Long Xia, Jie Jiang, Qin-Hui Sheng, Jing Zhou, Yan-Sheng Ding

Abstract read
In one paragraph

Article in Cardiology research and practice, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yu-Chuan WangDepartment of Geriatrics, Peking University First Hospital, Beijing, China.
Bo HuangDepartment of Geriatrics, Peking University First Hospital, Beijing, China.
Kang LiDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Peng-Kang HeDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Er-Dong ChenDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Yu-Long XiaDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Jie JiangDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Qin-Hui ShengDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Jing ZhouDepartment of Cardiology, Peking University First Hospital, Beijing, China.ORCID 0000-0002-8896-0019
Yan-Sheng DingDepartment of Cardiology, Peking University First Hospital, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo identify optimal predefined criteria (OPC) for filters of the VisiTag™ module in the CARTO 3 system during pulmonary vein isolation (PVI).

methodsThirty patients with atrial fibrillation (AF) who experienced PVI first were enrolled. PVI was accomplished by using a Thermocool SmartTouch catheter. Ablation lesions were tagged automatically as soon as predefined criteria of the VisiTag™ module were met. OPC should be that ablation with the setting resulting in the conduction gap (CG) as few as possible, while contiguous encircling ablation line (CEAL) without the tag gap (TG) on the 3D anatomic model as much as possible.

resultsWhen ablation with parameter setting is being catheter movement with a 3 mm distance limit for at least 20 s and force over time (FOT) being off, there were 60 CEAL without TG on the 3D anatomic model. However, 26 CGs were found. After changing FOT setting to be a minimal force of 5 g with 50% stability time, 22 TGs were displayed. Of them, 20 TGs were accompanied by CGs. On reablation at sites of TG with changed parameter setting, 18 CGs were eliminated when 20 TGs disappeared. When reablation with FOT is being a minimal force of 10 g with 50% stability time, 6 remaining CGs were eliminated. However, there was no CEAL. With a mean of follow-up 10.93 months, 2 patients with persistent AF suffered AF recurrence.

conclusionA 3 mm distance limit for at least 20 s and FOT being a minimal force of 5 g with 50% stability time might be OPC for the VisiTag™ module.

Identifiers

PMID30510796
PMCPMC6231390

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.