Evidence map›Paper›PMID 30510413›Full record

ArticleInternational journal of nanomedicine2018

A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging.

Luzhen Deng, Biao Wei, Peng He, Yi Zhang, Peng Feng

Abstract read
In one paragraph

Article in International journal of nanomedicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Luzhen DengKey Laboratory of Optoelectronics Technology and System, Chongqing University, Ministry of Education, Chongqing 400044, China, coe-fp@cqu.edu.cn.
Biao WeiKey Laboratory of Optoelectronics Technology and System, Chongqing University, Ministry of Education, Chongqing 400044, China, coe-fp@cqu.edu.cn.
Peng HeKey Laboratory of Optoelectronics Technology and System, Chongqing University, Ministry of Education, Chongqing 400044, China, coe-fp@cqu.edu.cn.
Yi ZhangCollege of Computer Science, Sichuan University, Chengdu 610065, China.
Peng FengKey Laboratory of Optoelectronics Technology and System, Chongqing University, Ministry of Education, Chongqing 400044, China, coe-fp@cqu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundX-ray fluorescence (XRF) computed tomography (XFCT) has shown promise for molecular imaging of metal nanoparticles such as gold nanoparticles (GNPs) and benchtop XFCT is under active development due to its easy access, low-cost instrumentation and operation. PURPOSE: To validate the performance of a Geant4-based Monte Carlo (MC) model of a benchtop multi-pinhole XFCT system for quantitative imaging of GNPs.

methodsThe MC mode consisted of a fan-beam x-ray source (125 kVp), which was used to stimulate the emission of XRF from the GNPs, a phantom (3 cm in diameter) which included six or nine inserts (3 mm in diameter), each of which contained the same (1 wt. %) or various (0.08-1 wt. %) concentrations of GNPs, a multi-pinhole collimator which could acquire multiple projections simultaneously and a one-sided or two-sided two-dimensional (2D) detector. Various pinhole diameters (3.7, 2, 1, 0.5 and 0.25 mm) and various particle numbers (20, 40, 80 and 100 billion) were simulated and the results for single pinhole and multi-pinhole (9 pinholes) imaging were compared.

resultsThe image resolution for a 1 mm multi-pinhole was between 0.88 and 1.38 mm. The detection limit for multi-pinhole operation was about 0.09 wt. %, while that for the single pinhole was about 0.13 wt. %. For a fixed number of pinholes, noise increased with decreasing number of photons.

conclusionThe MC mode could acquire 2D slice images of the object without rotation and demonstrated that a multi-pinhole XFCT imaging system could be a potential bioimaging modality for nanomedical applications.

Indexed as

Monte Carlo MethodOptical ImagingTomography, X-Ray ComputedFluorescenceGoldImaging, Three-DimensionalLimit of DetectionMetal NanoparticlesPhantoms, ImagingPhotonsX-RaysGoldbioimaging modalityGeant4gold nanoparticlesMonte Carlo simulationmulti-pinholeX-ray fluorescence computed tomography

Identifiers

PMID30510413
PMCPMC6231504

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.