Evidence map›Paper›PMID 30506242›Full record

ArticleHernia : the journal of hernias and abdominal wall surgery2019

Laparoscopic transabdominal preperitoneal (TAPP) groin hernia repair using n-butyl-2-cyanoacrylate (Liquiband®Fix8™) for mesh fixation and peritoneal closure: learning experience during introduction into clinical practice.

P Wilson, L Hickey

Open access · hybridAbstract read
In one paragraph

Article in Hernia : the journal of hernias and abdominal wall surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. N-Butyl-2-Cyanoacrylate Adhesive Versus Absorbable Tacks in Laparoscopic Groin Hernia Repair: A Multicenter Randomized Clinical Trial.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2024
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Assessment of feasibility and safety of cyanoacrylate glue versus absorbable tacks for inguinal hernia mesh fixation. A prospective comparative study.Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2023
    Article
  10. Article
  11. Article
  12. Article
  13. Mesh fixation in IPOM with cyanoacrylate glue, a matter of surface area? Author's Reply.Hernia : the journal of hernias and abdominal wall surgery · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

P WilsonUniversity Hospitals of Morecambe Bay NHS Foundation Trust, Lancaster, UK. paul.wilson@mbht.nhs.uk.ORCID http://orcid.org/0000-0001-7777-4782
L HickeyUniversity Hospitals of Morecambe Bay NHS Foundation Trust, Lancaster, UK.
University Hospitals of Morecambe Bay NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn a single centre evaluation of a novel hernia repair device, 200 consecutive patients underwent 247 laparoscopic (TAPP) groin hernia repairs (47 bilateral) using n-butyl-2-cyanoacrylate (Liquiband®Fix8™) for mesh fixation and peritoneal closure over a 2-year period by a single experienced laparoscopic surgeon. PATIENTS AND

methodsAll groin hernia patients requiring TAPP repair were included in the study: Inguinal 142, Femoral 14, Spigelian 4, and Inguinal disruption 40. A retrospective review of the data was performed. There were 161 males and 39 females, mean age 55 years (range 20-89 years). Mesh fixation was successful in all 247 TAPP repairs, and 90% of patients had a successful peritoneal closure using the device (20 patients required the use of conventional tacks to complete closure). FOLLOW-UP: Patients were followed up with an out-patient visit at 6 weeks post-op, followed by a Patient Initiated Follow Up programme, and a final Telephone follow-up. To date all patients have completed 1 year of follow-up, and 70% of patients 2 years of follow-up (median 29 months, range 14 to 40 months).

resultsThere were very few procedure-related adverse events: groin seromas 6 (2.4%), port site bleeding 2 (0.3%), port site hernia 2 (0.3%), and only 1 groin hernia recurrence (0.4%). Prospective surgeon scoring of satisfaction for mesh fixation, peritoneal closure, and device clogging was favourable and increased following the initial learning phase. Changes in the device design during the study period improved the efficacy of the device significantly.

conclusionThis retrospective study shows that mesh fixation and peritoneal closure using the Liquiband®Fix8™ device is feasible, safe, practical, and is easy to learn.

Indexed as

Abdominal WallAdultAgedAged, 80 and overEnbucrilateFemaleGroinHernia, AbdominalHerniorrhaphyHumansLaparoscopyMaleMiddle AgedPeritoneumRetrospective StudiesSurgical MeshEnbucrilateTissue AdhesivesCyanoacrylate glueMesh fixationPeritoneal closureTAPP repair

Identifiers

PMID30506242
PMCPMC6586721
OpenAlexW2902312092

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.