Evidence map›Paper›PMID 30505410›Full record

ArticleClinics in orthopedic surgery2018

Safety of Temporary Use of Recycled Autoclaved Femoral Components in Infected Total Knee Arthroplasty: Confirming Sterility Using a Sonication Method.

Hyung-Jin Park, Hee-June Kim, Shukho Kim, Seong-Min Kim, Jong-Uk Mun, Jungmin Kim, Hee-Soo Kyung

Open access · diamondAbstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Temporary new implant spacers increase post-reimplantation total knee prosthesis survival after periprosthetic joint infection.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Hyung-Jin ParkDepartment of Orthopaedic Surgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Hee-June KimDepartment of Orthopaedic Surgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Shukho KimDepartment of Microbiology, School of Medicine, Kyungpook National University, Daegu, South Korea.
Seong-Min KimDepartment of Orthopaedic Surgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Jong-Uk MunDepartment of Orthopaedic Surgery, Gyeongsang National University Changwon Hospital, Changwon, South Korea.
Jungmin KimDepartment of Microbiology, School of Medicine, Kyungpook National University, Daegu, South Korea.
Hee-Soo KyungDepartment of Orthopaedic Surgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Kyungpook National University · KRKyungpook National University Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purpose of this study was to evaluate the usefulness of sonication technique for microbiological diagnosis and the sterility of the recycled autoclaved femoral components from infected total knee arthroplasty (TKA) using a sonication method.

methodsNineteen femoral implants explanted from patients with infected TKA were sterilized with a standard autoclave method. Standard culture of the fluid before and after sonication of the sterilized implants was performed to detect pathogenic microorganisms. Additional experiments were performed to evaluate the sterility of the recycled implant by inducing artificial biofilm formation. Methicillin-resistant

resultsTwo of the 19 sterilized implants were positive for growth of bacteria after sonication, whereas no growth was detected in the cultured fluid from the sterilized implants before sonication. The bacteria were

conclusionsWe found sonication for identification of pathogens could be helpful, but this finding should be interpreted carefully because of the possibility of contamination. Sterilization of an infected femoral implant with an autoclave method could be a good method for using the temporary articulating antibiotic spacer in two-stage revision arthroplasty.

Indexed as

Arthroplasty, Replacement, KneeHumansKnee ProsthesisMethicillin-Resistant Staphylococcus aureusProsthesis-Related InfectionsSonicationStaphylococcal InfectionsSterilizationInfectionPeriprosthetic joint infectionSonicationTotal knee arthroplasty

Identifiers

PMID30505410
PMCPMC6250973
OpenAlexW2900963849

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.