ArticleActa otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale2018
Radiologic measurement of cochlea and hearing preservation rate using slim straight electrode (CI422) and round window approach.
Article in Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 8 citations in OpenAlex.
- The Role of Cochlear Anatomy in Hearing Preservation After Cochlear Implantation in Adults: A Systematic Review.Laryngoscope investigative otolaryngology · 2026Review
- Cochlear implantation under local anesthesia and conscious sedation: an Italian experience.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2021Article
- Evaluation of artifacts of cochlear implant electrodes in cone beam computed tomography.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2021Article
- Preservation of residual hearing after cochlear implant surgery with slim modiolar electrode.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2020Article
- Hearing Preservation With the Use of Flex20 and Flex24 Electrodes in Patients With Partial Deafness.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hearing preservation surgery constitutes a considerable branch of cochlear implantation surgery and is being steadily developed and perfected. The aim of the study was to verify if insertion of a cochlear implant electrode according to individually calculated linear insertion depth improves hearing preservation. We evaluated the relations between the size of a cochlea, insertion depth angle, linear insertion depth and hearing preservation rate (HP) according to Hearing Preservation Classification in a retrospective case review of 54 patients implanted with a slim straight electrode Nucleus CI422 in 2008-2011. Group HP was 0.75 at activation, 0.67 at 12 months (for 53 patients) and 0.60 at 24 months. In 53 cases, the mean insertion depth angle was 375° (SD 17°); mean calculated cochlear duct length 35.87 mm (SD 1.95); mean calculated linear insertion depth 23.14 mm (SD 1.68). There was no significantly relevant relation between HP values and angular insertion depth or insertion depth. Preoperative measurements of cochlea and specific parameters such as linear insertion depth have no effect on hearing preservation. Poor hearing preservation in some deep insertion cases cannot be explained entirely by the electrode position.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.