Evidence map›Paper›PMID 30496792›Full record

ArticleMagnetic resonance imaging2019

7-Tesla MRI of the brain in a research subject with bilateral, total knee replacement implants: Case report and proposed safety guidelines.

Giuseppe Barisano, Bozena Culo, Frank G Shellock, Farshid Sepehrband, Katherin Martin, Mary Stevens, Danny J Wang, Arthur W Toga, Meng Law

Abstract readCase Reports
In one paragraph

Article in Magnetic resonance imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Safety for Human MR Scanners at 7T.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022
    Article
  3. Review
  4. Perivascular Space Imaging at Ultrahigh Field MR Imaging.Magnetic resonance imaging clinics of North America · 2021
    Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Giuseppe BarisanoDepartment of Radiology, Keck School of Medicine of University of Southern California, 1975 Zonal Ave, Los Angeles, CA 90033, United States of America; Stevens Neuroimaging and Informatics Institute, University of Southern California, 2025 Zonal Ave., Los Angeles, CA 90033, United States of America.
Bozena CuloLoyola Marymount University, 1 LMU Drive, Los Angeles, CA 90045, United States of America.
Frank G ShellockDepartment of Radiology, Keck School of Medicine of University of Southern California, 1975 Zonal Ave, Los Angeles, CA 90033, United States of America. Electronic address: frank.shellock@gte.net.
Farshid SepehrbandStevens Neuroimaging and Informatics Institute, University of Southern California, 2025 Zonal Ave., Los Angeles, CA 90033, United States of America.
Katherin MartinStevens Neuroimaging and Informatics Institute, University of Southern California, 2025 Zonal Ave., Los Angeles, CA 90033, United States of America.
Mary StevensStevens Neuroimaging and Informatics Institute, University of Southern California, 2025 Zonal Ave., Los Angeles, CA 90033, United States of America.
Danny J WangStevens Neuroimaging and Informatics Institute, University of Southern California, 2025 Zonal Ave., Los Angeles, CA 90033, United States of America.
Arthur W TogaStevens Neuroimaging and Informatics Institute, University of Southern California, 2025 Zonal Ave., Los Angeles, CA 90033, United States of America.
Meng LawDepartment of Radiology, Keck School of Medicine of University of Southern California, 1975 Zonal Ave, Los Angeles, CA 90033, United States of America.

Funding

NOVA PTX Coil for Ultrahigh Field ImagingS10OD025312 · OD · UNIVERSITY OF SOUTHERN CALIFORNIA · PI WANG, DANNY JJ · 2018 to 2018
$330k
NIH HHS S10 OD025312
6 · The paper itself

Abstract

Recently, the first 7-T MR system was approved for clinical use in the United States. Unfortunately, relatively few metallic implants have undergone testing to determine if they are acceptable or pose hazards to research subjects and patients at this ultra-high-field strength. Therefore, in lieu of not performing a research or clinical MRI exam at 7-T, the supervising physician may make a decision to scan the individual with an untested metallic implant based on an analysis of the risks vs. the benefits. We present a case report of a research subject with bilateral, total knee replacement implants that safely underwent MRI of the brain at 7-T and provide guidelines for healthcare professionals to follow in order to ensure safety in research subjects or patients with metallic implants referred for 7-T scans.

Indexed as

Arthroplasty, Replacement, KneeMagnetic Resonance ImagingMetalsArtifactsBrainFemaleHumansKnee ProsthesisMagnetic FieldsMiddle AgedPatient SafetyProstheses and ImplantsResearch SubjectsMetals7-TeslaBrainMagnetic resonance imaging (MRI)MRI implantsMRI safety

Identifiers

PMID30496792
PMCPMC9154312

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.