Evidence map›Paper›PMID 30486391›Full record

ArticleSensors (Basel, Switzerland)2018

A Fast Calibration and Compensation Method for Magnetometers in Strap-Down Spinning Projectiles.

Dafeng Long, Xiaoming Zhang, Xiaohui Wei, Zhongliang Luo, Jianzhong Cao

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
14.2field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Dafeng LongSchool of Electronic Information and Electrical Engineering, Huizhou University, Huizhou 516007, China. longdafeng@nuc.edu.cn.ORCID 0000-0002-2107-1444
Xiaoming ZhangScience and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China. axiauto_gps@163.com.
Xiaohui WeiSchool of Electronic Information and Electrical Engineering, Huizhou University, Huizhou 516007, China. weixh0509@hzu.edu.cn.
Zhongliang LuoSchool of Electronic Information and Electrical Engineering, Huizhou University, Huizhou 516007, China. hk3333@163.com.
Jianzhong CaoSchool of Electronic Information and Electrical Engineering, Huizhou University, Huizhou 516007, China. cjz@hzu.edu.cn.
Huizhou University · CNNorth University of China · CN

Funding

Innovative Research Team of Huizhou University (IRTHU) 201800101the National Natural Science Foundation of China 61004127
6 · The paper itself

Abstract

Attitude measurement is an essential technology in projectile trajectory correction. Magnetometers have been used for projectile attitude measurement systems as they are small in size, lightweight, and low cost. However, magnetometers are seriously disturbed by the artillery magnetic field during launch. Moreover, the error parameters of the magnetometers, which are calibrated in advance, usually change after extended storage. The changed parameters have negative effects on attitude estimation of the projectile. To improve the accuracy of attitude estimation, the magnetometers should be calibrated again before launch or during flight. This paper presents a fast calibration method specific for a spinning projectile. At the launch site, the tri-axial magnetometer is calibrated, the parameters of magnetometer are quickly obtained by optimal ellipsoid fitting based on a least squares criterion. Then, the calibration parameters are used to compensate for magnetometer outputs during flight. The numerical simulation results show that the proposed calibration method can effectively determine zero bias, scale factors, and alignment angle errors. Finally, a semi-physical experimental system was designed to further verify the performance of the calibration method. The results show that pitch angle error reduces from 3.52° to 0.58° after calibration. The roll angle error is reduced from 2.59° to 0.65°. Simulations and experimental results indicate that the accuracy of magnetometer in strap-down spinning projectile has been greatly enhanced, and the attitude estimation errors are reduced after calibration.

Indexed as

calibrationellipsoid fittingmagnetometerspinning projectile

Identifiers

PMID30486391
PMCPMC6308640
OpenAlexW2903108123

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked