ArticleWorld journal of emergency surgery : WJES2018
Vacuum-assisted closure (VAC®) systems and microbiological isolation of infected wounds.
Article in World journal of emergency surgery : WJES, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 16 citations in OpenAlex.
- Deep Sternal Wound Infection After Open-heart Cardiac Surgery and Vacuum-Assisted Closure Therapy: a Single-center Study.Medical archives (Sarajevo, Bosnia and Herzegovina) · 2022Observational
- Article
- Tapering pressure of wall vacuum-assisted closure for the treatment of patients with pancreatic fistula in traumatic pancreatic injury: Report of two cases.International journal of surgery case reports · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Negative pressure wound therapy is now largely used to treat infected wounds. The prevention and reduction of healthcare-associated infections is a high priority for any Department of Health and great efforts are spent to improve infection control systems. It is assumed that vacuum-assisted closure (VAC®) dressings should be watertight and that all the secretions are gathered in a single container but there is no consistent data on air leakage and possible dispersion of bacteria from the machine. Methods: We have conducted a prospective experimental study on 10 patients with diagnosis of wound infection to verify whether the filtration process is microbiologically efficient. We compared the bacteria population present in the wound to the one present in the air discharged by the VAC® machine. Results: This study shows that the contamination of the VAC® machine is considerably lower than the environment or wound contamination. Conclusions: Negative pressure wound therapy system does not represent a risk factor for healthcare-associated infections.