Evidence map›Paper›PMID 30478924›Full record

ArticleThe Laryngoscope2019

Automated Quantification of Vocal Fold Motion in a Recurrent Laryngeal Nerve Injury Mouse Model.

Megan M Haney, Ali Hamad, Emily Leary, Filiz Bunyak, Teresa E Lever

Open access · greenAbstract read
In one paragraph

Article in The Laryngoscope, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Megan M HaneyDepartment of Veterinary Pathobiology , University of Missouri, Columbia, Missouri, U.S.A.ORCID 0000-0001-8835-6906
Ali HamadDepartment of Electrical Engineering and Computer Science , University of Missouri, Columbia, Missouri, U.S.A.
Emily LearyDepartment of Orthopaedic Biostatistics , University of Missouri, Columbia, Missouri, U.S.A.
Filiz BunyakDepartment of Electrical Engineering and Computer Science , University of Missouri, Columbia, Missouri, U.S.A.
Teresa E LeverDepartment of Otolaryngology-Head and Neck Surgery , University of Missouri, Columbia, Missouri, U.S.A.
University of Missouri · USMissouri College · US

Funding

Postdoctoral Training in Comparative MedicineT32OD011126 · OD · UNIVERSITY OF MISSOURI-COLUMBIA · PI Elizabeth C Bryda, Aaron Ericsson · 2012 to 2026
$3.4M
POSTDOCTORAL TRAINING IN LABORATORY ANIMAL MEDICINET32RR007004 · NCRR · UNIVERSITY OF MISSOURI-COLUMBIA · PI BRYDA, ELIZABETH C, FRANKLIN, CRAIG L · 1985 to 2011
$3.3M
NCRR NIH HHS T32 RR007004NIH HHS T32 OD011126
6 · The paper itself

Abstract

objectives/hypothesisThe goal of this study was to objectively examine vocal fold (VF) motion dynamics after iatrogenic recurrent laryngeal nerve (RLN) injury in a mouse surgical model. Furthermore, we sought to identify a method of inducing injury with a consistent recovery pattern from which we can begin to evaluate spontaneous recovery and test therapeutic interventions. STUDY

designAnimal model.

methodsThe right RLN in C57BL/6J mice was crushed for 30 seconds using an aneurysm clip with 1.3-N closing force. Transoral laryngoscopy enabled visualization of VF movement prior to surgery, immediately post-crush, and at two endpoints: 3 days (n = 5) and 2 weeks (n = 5). VF motion was quantified with our custom motion-analysis software. At each endpoint, RLN samples were collected for transmission electron microscopy for correlation with VF motion dynamics.

resultsOur VF tracking software permitted automated quantification of several measures of VF dynamics, such as range and frequency of motion. By 2 weeks post-injury, the frequency of VF movement on the right (injured) side equaled the left, yet range of motion only partially recovered. These objective outcome measures enabled detection of VF dysfunction that persisted at 2 weeks post-crush. Transmission electron microscopy images revealed RLN degeneration 3 days post-crush and partial regeneration at 2 weeks, consistent with functional results obtained with automated VF tracking.

conclusionsOur motion-analysis software provides novel objective, quantitative, and repeatable metrics to detect and describe subtle VF dysfunction in mice that corresponds with underlying RLN degeneration and recovery. Adaptation of our tracking software for use with human patients is underway. LEVEL OF EVIDENCE: NA Laryngoscope, 129:E247-E254, 2019.

Indexed as

SoftwareAccelerometryAnimalsDisease Models, AnimalMiceMice, Inbred C57BLRecurrent Laryngeal NerveRecurrent Laryngeal Nerve InjuriesVocal Cordsautomated trackingmouseobjective quantificationRecurrent laryngeal nerve injuryvocal fold paralysis

Identifiers

PMID30478924
PMCPMC6535380
OpenAlexW2902140135

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.