Evidence map›Paper›PMID 30478470›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2019

Peripheral fixation of meniscal allograft does not reduce coronal extrusion under physiological load.

Christopher Hewison, Sandra Kolaczek, Scott Caterine, Rebecca Berardelli, Tyler Beveridge, Tim Lording, Jason Akindolire, Ben Herman, Mark Hurtig, Karen Gordon and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. The anatomy of Kaplan fibers.Archives of orthopaedic and trauma surgery · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 3 countries.

Christopher HewisonUniversity of Calgary, Calgary, Canada.
Sandra KolaczekSchool of Engineering, University of Guelph, Guelph, Canada.
Scott CaterineRoyal College of Surgeons Ireland, Dublin, Ireland.
Rebecca BerardelliFowler Kennedy Sport Medicine Clinic, Western University, London, Canada.
Tyler BeveridgeDepartment of Anatomy, Western University, London, Canada.
Tim LordingMelbourne Orthopaedic Group, Melbourne, Australia.
Jason AkindolireFowler Kennedy Sport Medicine Clinic, Western University, London, Canada.
Ben HermanFowler Kennedy Sport Medicine Clinic, Western University, London, Canada.
Mark HurtigOntario Veterinary College, University of Guelph, Guelph, Canada.
Karen GordonUniversity of Calgary, Calgary, Canada.
Alan GetgoodFowler Kennedy Sport Medicine Clinic, Western University, London, Canada. alan.getgood@uwo.ca.ORCID http://orcid.org/0000-0003-4731-4333
Western University · CAUniversity of Calgary · CAUniversity of Guelph · CAHollywood Orthopaedic Group · AURoyal College of Surgeons in Ireland · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMeniscal graft extrusion is a concern following meniscal allograft transplantation (MAT). MAT surgical techniques continue to evolve in an effort to reduce extrusion; however, improvements remain difficult to measure in vivo. A novel MRI-compatible in vitro loading device capable of applying physiologically relevant loads has been developed, allowing for the measurement of extrusion under a variety of controllable conditions. The objective of this study was to compare maximal medial MAT extrusion (1) with and (2) without an additional peripheral third point of fixation on the tibial plateau.

methodsTwelve human cadaveric knees underwent medial MAT, utilizing soft tissue anterior and posterior root fixation via transosseous suture, with a third transosseous suture tied over a button providing peripheral fixation on the tibial plateau. The joint was positioned at 5 degrees of flexion and loaded to 1 × body weight (647.7 ± 159.0 N) during MR image acquisition, with and without peripheral fixation. The joint was then positioned at 30 degrees of flexion and the process was repeated. Maximal coronal extrusion was measured.

resultsAn increase in maximal coronal meniscal extrusion was noted between the unloaded and loaded states. At 30 degrees of flexion, with the addition of a peripheral fixation point, a statistically significant difference in absolute extrusion (p = 0.02) and relative percent extrusion (p = 0.04) between the unloaded and loaded state was found. The addition of a peripheral fixation suture resulted in an overall mean percent difference of - 2.49% (SD 14.1; 95% CI - 11.95, 6.97; n.s.) in extrusion at 5 degrees of flexion and a mean percent difference of - 0.95% (SD 7.3; 95% CI - 5.62, 3.71; n.s.) in extrusion at 30 degrees of flexion. These differences were not statistically significant.

conclusionThese results suggest that the addition of a peripheral anchor in medial MAT does not reduce the amount of maximal coronal extrusion and, therefore, may not confer any clinical benefit. Surgical techniques utilized to reduce MAT extrusion need further investigation to understand if the added technical difficulty and potential expense is warranted.

Indexed as

Suture TechniquesAgedAllograftsCadaverFemaleHumansKnee JointMagnetic Resonance ImagingMaleMenisci, TibialOrthopedic ProceduresPlastic Surgery ProceduresPostoperative ComplicationsRange of Motion, ArticularTransplantation, HomologousGraft extrusionMATMeniscusMeniscus allograft transplantation

Identifiers

PMID30478470
OpenAlexW2902655301

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.