ArticleACS sensors2018
Tethered Bichromophoric Fluorophore Quencher Voltage Sensitive Dyes.
Article in ACS sensors, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Reaction of Picolinamides with Ketones Producing a New Type of Heterocyclic Salts with an Imidazolidin-4-One Ring.Molecules (Basel, Switzerland) · 2023Article
- Near-infrared voltage-sensitive dyes based on chromene donor.Proceedings of the National Academy of Sciences of the United States of America · 2023Article
- Current Practice in Using Voltage Imaging to Record Fast Neuronal Activity: Successful Examples from Invertebrate to Mammalian Studies.Biosensors · 2023Review
- Pyridine Carboxamides Based on Sulfobetaines: Design, Reactivity, and Biological Activity.Molecules (Basel, Switzerland) · 2022Article
- Next-Generation Diprovocims with Potent Human and Murine TLR1/TLR2 Agonist Activity That Activate the Innate and Adaptive Immune Response.Journal of medicinal chemistry · 2022Article
- Linearly polarized excitation enhances signals from fluorescent voltage indicators.Biophysical journal · 2021Article
- Point-localized, site-specific membrane potential optical recording by single fluorescent nanodiscs.Biophysical reports · 2021Article
- Small Molecule-Protein Hybrid for Voltage Imaging via Quenching of Bioluminescence.ACS sensors · 2021Article
- Recent progress in optical voltage-sensor technology and applications to cardiac research: from single cells to whole hearts.Progress in biophysics and molecular biology · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Voltage sensitive dyes (VSDs) are used for in vitro drug screening and for imaging of patterns of electrical activity in tissue. Wide application of this technology depends on the availability of sensors with high sensitivity (percent change of fluorescence per 100 mV), high fluorescence quantum yield, and fast response kinetics. A promising approach uses a two-component system consisting of anionic membrane permeable quenchers with fluorophores labeling one side of the membrane; this produces voltage-dependent fluorescence quenching. However, the quencher must be kept at low concentrations to minimize pharmacological effects, thus limiting sensitivity. By developing tethered bichromophoric fluorophore quencher (TBFQ) dyes, where the fluorophore and quencher are covalently connected by a long hydrophobic chain, the sensitivity is maximized and is independent of VSD concentration. A series of 13 TBFQ dyes based on the aminonaphthylethenylpyridinium (ANEP) fluorophore and the dipicrylamine anion (DPA) quencher have been synthesized and tested in an artificial lipid bilayer apparatus. The best of these, TBFQ1, shows a 2.5-fold change in fluorescence per 100 mV change in membrane potential, and the response kinetics is in the 10-20 ms range. This sensitivity is an order of magnitude better than that of commonly used VSDs. However, the fluorescence quantum yield is only 1.6%, which may make this first generation of TBFQ VSDs impractical for in vivo electrical imaging. Nevertheless, the design principles established here can serve as foundation for improved TBFQ VSDs. We believe this approach promises to greatly enhance our ability to monitor electrical activity in cells and tissues.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.