Evidence map›Paper›PMID 30473831›Full record

ArticleRoyal Society open science2018

Rapid detection of cocaine using aptamer-based biosensor on an evanescent wave fibre platform.

Yong Qiu, Yunfei Tang, Bing Li, Miao He

Open access · goldAbstract read
In one paragraph

Article in Royal Society open science, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Review
  8. Interpol review of controlled substances 2016-2019.Forensic science international. Synergy · 2020
    Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Yong QiuState Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, People's Republic of China.ORCID 0000-0001-5423-6869
Yunfei TangState Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, People's Republic of China.
Bing LiSchool of Energy and Environmental Engineering, University of Beijing Science and Technology, Beijing 100083, People's Republic of China.
Miao HeState Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, People's Republic of China.
State Key Joint Laboratory of Environment Simulation and Pollution Control · CNUniversity of Science and Technology Beijing · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The rapid detection of cocaine has received considerable attention because of the instantaneous and adverse effects of cocaine overdose on human health. Aptamer-based biosensors for cocaine detection have been well established for research and application. However, reducing the analytic duration without deteriorating the sensitivity still remains as a challenge. Here, we proposed an aptamer-based evanescent wave fibre (EWF) biosensor to rapidly detect cocaine in a wide working range. At first, the aptamers were conjugated to complementary DNA with fluorescence tag and such conjugants were then immobilized on magnetic beads. After cocaine was introduced to compete against the aptamer-DNA conjugants, the released DNA in supernatant was detected on the EWF platform. The dynamic curves of EWF signals could be interpreted by the first-order kinetics and saturation model. The semi-log calibration curve covered a working range of 10-5000 µM of cocaine, and the limit of detection was approximately 10.5 µM. The duration of the full procedure was 990 s (16.5 min), and the detection interval was 390 s (6.5 min). The specified detection of cocaine was confirmed from four typical pharmaceutic agents. The analysis was repeated for 50 cycles without significant loss of sensitivity. Therefore, the aptamer-based EWF biosensor is a feasible solution to rapidly detect cocaine.

Indexed as

aptamercocainecompetitive affinityevanescent wave fibre biosensorrapid detectionreproducibility

Identifiers

PMID30473831
PMCPMC6227954
OpenAlexW2896696864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.