Evidence map›Paper›PMID 30468044›Full record

ArticleJournal of biomedical optics2018

Cherenkov excited short-wavelength infrared fluorescence imaging in vivo with external beam radiation.

Xu Cao, Shudong Jiang, Mengyu Jeremy Jia, Jason R Gunn, Tianshun Miao, Scott C Davis, Petr Bruza, Brian W Pogue

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Real-time motion tracking of a gold implant in water by Cherenkov lights.Journal of applied clinical medical physics · 2026
    Article
  3. Review
  4. Detection of Shortwave-Infrared Cerenkov Luminescence from Medical Isotopes.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2023
    Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Xu CaoDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Shudong JiangDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Mengyu Jeremy JiaDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Jason R GunnDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Tianshun MiaoDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Scott C DavisDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Petr BruzaDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Brian W PogueDartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States.
Dartmouth College · USXidian University · CN

Funding

Cerenkov excited luminescence sheet imaging (CELSI)R01EB024498 · NIBIB · DARTMOUTH COLLEGE · PI POGUE, BRIAN WILLIAM · 2017 to 2020
$2.2M
NIBIB NIH HHS R01 EB024498
6 · The paper itself

Abstract

Cherenkov emission induced by external beam radiation therapy from a clinical linear accelerator (LINAC) can be used to excite phosphors deep in biological tissues. As with all luminescence imaging, there is a desire to minimize the spectral overlap between the excitation light and emission wavelengths, here between the Cherenkov and the phosphor. Cherenkov excited short-wavelength infrared (SWIR, 1000 to 1700 nm) fluorescence imaging has been demonstrated for the first time, using long Stokes-shift fluorophore PdSe quantum dots (QD) with nanosecond lifetime and an optimized SWIR detection. The 1  /  λ2 intensity spectrum characteristic of Cherenkov emission leads to low overlap of this into the fluorescence spectrum of PdSe QDs in the SWIR range. Additionally, using a SWIR camera itself inherently ignores the stronger Cherenkov emission wavelengths dominant across the visible spectrum. The SWIR luminescence was shown to extend the depth sensitivity of Cherenkov imaging, which could be used for applications in radiotherapy sensing and imaging in human tissue with targeted molecular probes.

Indexed as

Infrared RaysAnimalsMicePhantoms, ImagingRadiation MonitoringRadiotherapyCherenkov emissionfluorescence imagingradiationshort-wavelength infrared

Identifiers

PMID30468044
PMCPMC6250216
OpenAlexW2900856874

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.