Evidence map›Paper›PMID 30465327›Full record

ArticleInfection2019

Dialysis drains as a possible source for carbapenem-resistant pathogens causing an ICU outbreak.

Birgit Ross, Marco Krull, Peter Rath, Andreas Kribben, Dana Dopadlik, Irmgard Erlemann, Ina Wiegard-Szramek, Bartosz Tyczynski, Jan Buer, Frank Herbstreit

Abstract read
PubMed Publisher
In one paragraph

Article in Infection, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Bundesgesundheitsblatt, Gesundheitsforschung, Gesundheitsschutz · 2020
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Birgit RossKrankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany. birgit.ross@uk-essen.de.
Marco KrullKrankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany.
Peter RathInstitut für Medizinische Mikrobiologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany.
Andreas KribbenKlinik für Nephrologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany.
Dana DopadlikKrankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany.
Irmgard ErlemannKrankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany.
Ina Wiegard-SzramekKlinik für Nephrologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany.
Bartosz TyczynskiKlinik für Nephrologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany.
Jan BuerInstitut für Medizinische Mikrobiologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany.
Frank HerbstreitKlinik für Anästhesiologie and Intensivmedizin, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany.
Essen University Hospital · DEUniversity of Duisburg-Essen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

OBJECTIVE

designWe describe a case series of patients colonized with KPC-producing Enterobacteriaceae related to dialysis drains at patient's bedside.

settingThe study was set at the intensive care unit (ICU) of a tertiary referral hospital. PATIENTS: In March 2016, we discovered four ICU patients to be colonized with KPC-producing Enterobacteriaceae in routine screening. All of these patients had already received contact isolation, and all of them were treated with continuous veno-venous dialysis. Environmental examinations showed KPC-producing Enterobacteriaceae in dialysis drains in different ICU rooms and even in rooms not hosting KPC-colonized patients.

interventionsBased on our findings, we suspected the dialysis drains as a reservoir of KPC-producing Enterobacteriaceae with a potential risk for the patients. Therefore, we decided to change the dialysis waste management.

resultsAs a result, no KCP-producing Enterobacteriaceae were detected during the following weekly screening of the patients.

conclusionsInstallation of dialysis connection units including a drain system at the patient's bedside is a comfortable way to provide water supply. In many ICUs, such dialysis drains are installed near the patients' head and directly besides the infusion systems. When the drains are not used properly, in our opinion, they pose a risk of transmission of pathogens from the drain to the patient. Our findings support the need of specific precautions.

Indexed as

Disease OutbreaksDrug Resistance, BacterialCarbapenemsCross InfectionGermanyIntensive Care UnitsRenal DialysisTertiary Care CentersCarbapenemsCarbapenem resistanceDialysis drainsDialysis wastewaterICU

Identifiers

PMID30465327
OpenAlexW2901237326

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.