Evidence map›Paper›PMID 30463191›Full record

ArticleSensors (Basel, Switzerland)2018

Significant Sensitivity Improvement for Camera-Based Lateral Flow Immunoassay Readers.

Lalita Saisin, Ratthasart Amarit, Armote Somboonkaew, Oraprapai Gajanandana, Orawan Himananto, Boonsong Sutapun

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Magnetic Lateral Flow Immunoassays.Diagnostics (Basel, Switzerland) · 2020
    Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Lalita SaisinSchool of Electronic Engineering, Institute of Engineering, Suranaree University of Technology, 111 University Ave., Muang, Nakhon Ratchasima 30000, Thailand. gulalita_zcg@hotmail.com.
Ratthasart AmaritPhotonics Technology Laboratory, National Electronics and Computer Technology Center, 112 Thailand Science Park, Phahon Yothin Rd., Pathumthai 12120, Thailand. ratthasart.amarit@nectec.or.th.
Armote SomboonkaewPhotonics Technology Laboratory, National Electronics and Computer Technology Center, 112 Thailand Science Park, Phahon Yothin Rd., Pathumthai 12120, Thailand. Armote.Somboonkaew@nectec.or.th.
Oraprapai GajanandanaNational Center for Genetic Engineering and Biotechnology, 113 Thailand Science Park, Phahon Yothin Rd., Pathumthai 12120, Thailand. oraprapai@biotec.or.th.
Orawan HimanantoNational Center for Genetic Engineering and Biotechnology, 113 Thailand Science Park, Phahon Yothin Rd., Pathumthai 12120, Thailand. orawanh@biotec.or.th.
Boonsong SutapunSchool of Electronic Engineering, Institute of Engineering, Suranaree University of Technology, 111 University Ave., Muang, Nakhon Ratchasima 30000, Thailand. boonsong@sut.ac.th.
National Center for Genetic Engineering and Biotechnology · THNational Electronics and Computer Technology Center · THSuranaree University of Technology · TH

Funding

National Science and Technology Development Agency P-14-50467
6 · The paper itself

Abstract

Recent developments in smartphone-based strip readers have further improved the performances of lateral flow test kits. Most smartphone cameras encode an unaltered and nonlinear power-law transfer function that maps the light intensity to a pixel value; this poses some limitations for camera-based strip readers. For faint-color test lines which are almost as white such as with nitrocellulose pads, the slope of the transfer function is low. Therefore, it is difficult to differentiate between the faint test lines and the white background. We show that by manually setting the camera exposure time-instead of using the automatic settings-to the high-slope region of the transfer function, the reader's sensitivity can be improved. We found that the sensitivity and the limit of detection of the

Indexed as

ComamonadaceaeImmunoassayLimit of DetectionPhotographyPlant DiseasesSmartphonelateral flow immunoassaysLFA readersmartphone readerstrip readertest kits

Identifiers

PMID30463191
PMCPMC6263405
OpenAlexW2901810158

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.