Robust reconstruction of local optic axis orientation with fiber-based polarization-sensitive optical coherence tomography.

Qingyun Li, Karol Karnowski, Peter B Noble, Alvenia Cairncross, Alan James, Martin Villiger, David D Sampson

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 60 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Observational
  7. Article
  8. Translating endobronchial optical coherence tomography to clinical practice.American journal of physiology. Lung cellular and molecular physiology · 2024
    Article
  9. Article
  10. Journal of biomedical optics · 2023
    Article
  11. Article
  12. Article
  13. Article
  14. Biomedical optics express · 2022
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

Qingyun LiOptical + Biomedical Engineering Laboratory, Department of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, WA 6009, Australia.
Karol KarnowskiOptical + Biomedical Engineering Laboratory, Department of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, WA 6009, Australia.
Peter B NobleSchool of Human Sciences, The University of Western Australia, Perth, WA 6009, Australia.
Alvenia CairncrossSchool of Human Sciences, The University of Western Australia, Perth, WA 6009, Australia.
Alan JamesDepartment of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Perth, Australia.
Martin VilligerWellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA.
David D SampsonOptical + Biomedical Engineering Laboratory, Department of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, WA 6009, Australia.
The University of Western Australia · AUHarvard University · USSir Charles Gairdner Hospital · AU

Funding

TRD3: Percutaneous and Interstitial ImagingP41EB015903 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Brett E Bouma · 2012 to 2026
$22.4M
NIBIB NIH HHS P41 EB015903
6 · The paper itself

Abstract

It is challenging to recover local optic axis orientation from samples probed with fiber-based polarization-sensitive optical coherence tomography (PS-OCT). In addition to the effect of preceding tissue layers, the transmission through fiber and system elements, and imperfect system alignment, need to be compensated. Here, we present a method to retrieve the required correction factors from measurements with depth-multiplexed PS-OCT, which accurately measures the full Jones matrix. The correction considers both retardation and diattenuation and is applied in the wavenumber domain, preserving the axial resolution of the system. The robustness of the method is validated by measuring a birefringence phantom with a misaligned system. Imaging