ArticleEuropean radiology2019

Risk assessment of copper-containing contraceptives: the impact for women with implanted intrauterine devices during clinical MRI and CT examinations.

Wiebke Neumann, Tanja Uhrig, Matthias Malzacher, Verena Kossmann, Lothar R Schad, Frank G Zoellner

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Wiebke NeumannComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany. Wiebke.Neumann@medma.uni-heidelberg.de.ORCID http://orcid.org/0000-0002-9950-3817
Tanja UhrigComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany.
Matthias MalzacherComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany.
Verena KossmannComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany.
Lothar R SchadComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany.
Frank G ZoellnerComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany.
Heidelberg University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo assess the risks for implant users with copper-containing intrauterine devices (IUDs) during MR and CT examinations.

methodsA tissue-mimicking phantom suitable for all experiments within this study was developed. Seven different types of copper IUDs were evaluated. Heating and dislocation of each IUD were investigated at two clinically relevant positions in 1.5 T and 3 T MR scanners. Artifacts in the field of view caused by each tested IUD were determined for clinical MR and CT imaging.

resultsNo significant heating of any tested IUD was detected during MR measurements. The temperature increase was less than 0.6 K for all IUDs. Neither angular deflection nor translation of any IUD was detected. Artifacts in MR images were limited to the very vicinity of the IUDs except for one IUD containing a steel-visualizing element. Streaking artifacts in CT were severe (up to 75.5%) in the slices including the IUD.

conclusionNo significant risk possibly harming the patient was determined during this phantom study, deeming MR examinations safe for women with an implanted copper IUD. Image quality was more impaired for CT than for MR imaging and needs careful consideration during diagnosis. KEY POINTS: • Risk assessment of copper-containing IUDs with regard to heating, dislocation, and artifacts during MR and CT imaging. • Neither significant heating nor dislocation was determined in MR; image quality was more impaired for CT than for MR imaging and needs careful consideration during diagnosis. • The tested IUDs pose no additional risks for implant users during MR and CT examinations.

Indexed as

ArtifactsRisk AssessmentAdultContraceptive AgentsFemaleHumansIntrauterine Devices, CopperMagnetic Resonance ImagingPatient SafetyTomography, X-Ray ComputedContraceptive AgentsIntrauterine devices, copperMagnetic resonance imagingPatient safetyPhantoms, imagingTomography, X-ray computed

Identifiers

PMID30456586
OpenAlexW2901615097

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.