Evidence map›Paper›PMID 30456463›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2019

Incidence and impact of prosthesis-patient mismatch following transcatheter aortic valve implantation.

Hatim Seoudy, Nathalie Güßefeld, Johanne Frank, Sandra Freitag-Wolf, Georg Lutter, Matthias Eden, Ashraf Yusuf Rangrez, Christian Kuhn, Norbert Frey, Derk Frank

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Hemodynamics of self-expanding versus balloon-expandable transcatheter heart valves in relation to native aortic annulus anatomy.Clinical research in cardiology : official journal of the German Cardiac Society · 2022
    Article
  3. Article
  4. Article
  5. Machine learning-based risk prediction of intrahospital clinical outcomes in patients undergoing TAVI.Clinical research in cardiology : official journal of the German Cardiac Society · 2021
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hatim SeoudyDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.
Nathalie GüßefeldDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.
Johanne FrankDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.
Sandra Freitag-WolfDepartment of Medical Informatics and Statistics, University Hospital Schleswig-Holstein, Kiel, Germany.
Georg LutterDepartment of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Kiel, Germany.
Matthias EdenDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.
Ashraf Yusuf RangrezDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.
Christian KuhnDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.
Norbert FreyDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.
Derk FrankDepartment of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany. derk.frank@uksh.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe implications of prosthesis-patient mismatch (PPM) in the context of transcatheter aortic valve implantation (TAVI) are still controversial. The objective of our study was thus to investigate the incidence and prognostic impact of PPM after TAVI.

methodsOur analysis included 613 TAVI patients in whom the indexed effective orifice area (iEOA) after TAVI was obtained in vivo using echocardiography. Prosthesis sizing was guided by pre-procedural ECG-gated computed tomography. Based on VARC-2 established criteria for significant PPM (iEOA ≤ 0.85 cm

resultsWe observed PPM after TAVI in 192 patients (31.3%) with moderate PPM being present in 150 subjects (24.5%) and severe PPM in 42 patients (6.9%). EuroSCORE, impaired LV function, and male gender were associated with PPM status. The "No PPM" group was characterized by higher rates of self-expandable valves (40.4% vs. 25.5%, p < 0.001). In a multivariate analysis age > 81.2 years, chronic obstructive pulmonary disease, peripheral artery disease, impaired LV function, acute kidney failure stage 3 as well as periprocedural myocardial infarction emerged as independent risk predictors for all-cause mortality after TAVI. After a median follow-up of 12.2 months PPM failed to show a significant association with overall survival (79.2% vs. 79.3%, p = 0.692).

conclusionsThe incidence of PPM after TAVI seems to be substantially lower than after SAVR. PPM was less common using self-expandable valves. In our analysis, patients with PPM following TAVI did not have higher rates of all-cause mortality.

Indexed as

Heart Valve ProsthesisProsthesis DesignAgedAged, 80 and overAortic ValveFemaleGermanyHumansIncidenceMalePostoperative ComplicationsRetrospective StudiesRisk AssessmentRisk FactorsTime FactorsTranscatheter Aortic Valve ReplacementAortic stenosisTranscatheter aortic valve implantationValvular heart disease

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.