ArticleDocumenta ophthalmologica. Advances in ophthalmology2019
Toxicity and in vivo release profile of sirolimus from implants into the vitreous of rabbits' eyes.
Article in Documenta ophthalmologica. Advances in ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 14 citations in OpenAlex.
- Intraocular therapy in noninfectious uveitis.Journal of ophthalmic inflammation and infection · 2021Review
- Human Stem Cell-Derived Retinal Pigment Epithelial Cells as a Model for Drug Screening and Pre-Clinical Assays Compared to ARPE-19 Cell Line.International journal of stem cells · 2021Article
- A comprehensive review of intravitreal immunosuppressants and biologicals used in ophthalmology.Therapeutic advances in ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo assess the in vivo release profile and the retinal toxicity of a poly (lactic-co-glycolic acid) (PLGA) sustained-release sirolimus (SRL) intravitreal implant in normal rabbit eyes.
methodsPLGA intravitreal implants containing or not SRL were prepared, and the viability of ARPE-19 and hES-RPE human retinal cell lines was examined after 24 and 72 h of exposure to implants. New Zealand rabbits were randomly divided into two groups that received intravitreal implants containing or not SRL. At each time point (1-8 weeks), four animals from the SRL group were euthanized, the vitreous was collected, and drug concentration was calculated. Clinical evaluation of the eyes was performed weekly for 8 weeks after administration. Electroretinography (ERG) was recorded in other eight animals, four for each group, at baseline and at 24 h, 1, 4, 6, and 8 weeks after the injection. ERG was carried out using scotopic and photopic protocols. The safety of the implants was assessed using statistical analysis of the ERG parameters (a and b waves, a and b implicit time, B/A ratio, oscillatory potential, and Naka-Rushton analysis) comparing the functional integrity of the retina between the PLGA and SRL-PLGA groups. After the last electrophysiological assessment, the rabbits were euthanized and retinal histopathology was realized.
resultsAfter 24 and 72 h of incubation with PLGA or SRL-PLGA implants, ARPE-19 and hES-RPE cells showed viability over 70%. The maximum concentration of SRL (199.8 ng/mL) released from the device occurred within 4 weeks. No toxic effects of the implants or increase in the intraocular pressure was observed through clinical evaluation of the eye. ERG responses showed no significant difference between the eyes that received PLGA or SRL-PLGA implants at baseline and throughout the 8 weeks of follow-up. No remarkable difference in retinal histopathology was detected in rabbit eyes treated with PLGA or SRL-PLGA implants.
conclusionsIntravitreal PLGA or SRL-PLGA implants caused no significant reduction in cell viability and showed no evident toxic effect on the function or structure of the retina of the animals. SRL was released from PLGA implant after application in the vitreous of rabbits during 8 weeks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.