Evidence map›Paper›PMID 30453609›Full record

ArticleSensors (Basel, Switzerland)2018

A Novel Microfluidic Point-of-Care Biosensor System on Printed Circuit Board for Cytokine Detection.

Daniel Evans, Konstantinos I Papadimitriou, Nikolaos Vasilakis, Panagiotis Pantelidis, Peter Kelleher, Hywel Morgan, Themistoklis Prodromakis

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.8field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 56 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
  9. Cytokines: From Clinical Significance to Quantification.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Daniel EvansNanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK. dan_evans@outlook.com.
Konstantinos I PapadimitriouNanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK. k.papadimitriou@ucl.ac.uk.ORCID 0000-0002-0995-4834
Nikolaos VasilakisNanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK. n.vasilakis@soton.ac.uk.
Panagiotis PantelidisCentre for Immunology and Vaccinology, Division of Infectious Diseases, Department of Medicine, Imperial College London, London SW10 9NH, UK. panagiotis.pantelidis@nhs.net.
Peter KelleherCentre for Immunology and Vaccinology, Division of Infectious Diseases, Department of Medicine, Imperial College London, London SW10 9NH, UK. p.kelleher@imperial.ac.uk.
Hywel MorganNanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK. hm@ecs.soton.ac.uk.
Themistoklis ProdromakisZepler Institute for Photonics and Nanoelectronics, University of Southampton, Southampton SO17 1BJ, UK. t.prodromakis@soton.ac.uk.
University of Southampton · GBCharing Cross Hospital · GB

Funding

Engineering and Physical Sciences Research Council EP/L020920/1
6 · The paper itself

Abstract

Point of Care (PoC) diagnostics have been the subject of considerable research over the last few decades driven by the pressure to detect diseases quickly and effectively and reduce healthcare costs. Herein, we demonstrate a novel, fully integrated, microfluidic amperometric enzyme-linked immunosorbent assay (ELISA) prototype using a commercial interferon gamma release assay (IGRA) as a model antibody binding system. Microfluidic assay chemistry was engineered to take place on Au-plated electrodes within an assay cell on a printed circuit board (PCB)-based biosensor system. The assay cell is linked to an electrochemical reporter cell comprising microfluidic architecture, Au working and counter electrodes and a Ag/AgCl reference electrode, all manufactured exclusively via standard commercial PCB fabrication processes. Assay chemistry has been optimised for microfluidic diffusion kinetics to function under continual flow. We characterised the electrode integrity of the developed platforms with reference to biological sampling and buffer composition and subsequently we demonstrated concentration-dependent measurements of H₂O₂ depletion as resolved by existing FDA-validated ELISA kits. Finally, we validated the assay technology in both buffer and serum and demonstrate limits of detection comparable to high-end commercial systems with the addition of full microfluidic assay architecture capable of returning diagnostic analyses in approximately eight minutes.

Indexed as

Biosensing TechniquesPoint-of-Care SystemsCytokinesElectrochemical TechniquesElectrodesHumansHydrogen PeroxideInterferon-gammaLimit of DetectionMicrofluidicsCytokinesHydrogen PeroxideInterferon-gammacytokine detectioneELISAlab-on-PCBmicrofluidicsPCB biosensorspoint-of-care diagnostics

Identifiers

PMID30453609
PMCPMC6264023
OpenAlexW2900636560

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked