A quantitative comparison of five optical coherence tomography angiography systems in clinical performance.

Xin-Xin Li, Wei Wu, Hao Zhou, Jun-Jie Deng, Meng-Ya Zhao, Tian-Wei Qian, Chen Yan, Xun Xu, Su-Qin Yu

Abstract read
In one paragraph

Article in International journal of ophthalmology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 42 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
42citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

42 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. The march to harmonized imaging standards for retinal imaging.Progress in retinal and eye research · 2025
    Review
  10. Article
  11. Review
  12. Article
  13. Optical coherence tomography angiography in diabetic retinopathy.Progress in retinal and eye research · 2023
    Review
  14. Observational
  15. Review
  16. Review
  17. Article
  18. Review
  19. Review
  20. Choriocapillaris flow loss in center-involving retinitis pigmentosa: a quantitative optical coherence tomography angiography study using a novel classification system.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xin-Xin LiDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.
Wei WuDepartment of Mathematics, Eidgenössische Technische Hochschule Zürich, Zurich 8092, Switzerland.
Hao ZhouDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.
Jun-Jie DengDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.
Meng-Ya ZhaoDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.
Tian-Wei QianDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.
Chen YanDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.
Xun XuDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.
Su-Qin YuDepartment of Ophthalmology, Shanghai General Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200080, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo compare the clinical performance of 4 spectral-domain (SD) optical coherence tomography angiography (OCTA) systems: AngioVue™, AngioPlex™, Spectralis

methodsTwenty-seven undilated right eyes of 27 participants underwent OCTA examination using five different systems respectively for both 3×3 and 6×6 mm

resultsThe age of the subjects was 28.19±5.55y (range, 23-49y). The spherical equivalent refraction was -2.55±1.84 D (range, 0.00 to -5.25 D). Significant difference was observed in the evaluation of vessel valid visibility (AngioVue the highest: 0.111±0.031 for 3×3 mm

conclusionThere is poor agreement of measurements among systems. AngioVue provides images with the highest vessel valid visibility and the fewest motion artifacts. AngioPlex achieves the shortest acquisition.

Indexed as

acquisition timedevicesmotion artifactsoptical coherence tomography angiographyvessel valid visibility

Identifiers

PMID30450309
PMCPMC6232334

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.