Evidence map›Paper›PMID 30431030›Full record

ArticleNanoscale2018

Measurement of cytokine biomarkers using an aptamer-based affinity graphene nanosensor on a flexible substrate toward wearable applications.

Zhuang Hao, Ziran Wang, Yijun Li, Yibo Zhu, Xuejun Wang, Carlos Gustavo De Moraes, Yunlu Pan, Xuezeng Zhao, Qiao Lin

Abstract read
In one paragraph

Article in Nanoscale, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.

0numbers the graph read from it
0cells of the map it votes in
38citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

38 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Monitoring CdNanoscale advances · 2023
    Article
  12. Smart Wearable Systems for Health Monitoring.Sensors (Basel, Switzerland) · 2023
    Review
  13. Review
  14. Advances in flexible graphene field-effect transistors for biomolecule sensing.Frontiers in bioengineering and biotechnology · 2023
    Review
  15. In vitro selection of aptamers and their applications.Nature reviews. Methods primers · 2023
    Article
  16. Article
  17. Review
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zhuang HaoDepartment of Mechanical Engineering, Columbia University, New York, NY 10027, USA. qlin@columbia.edu.
Ziran Wang
Yijun Li
Yibo Zhu
Xuejun Wang
Carlos Gustavo De Moraes
Yunlu Pan
Xuezeng Zhao
Qiao Lin

Funding

Validating Rapid Microfluidic Isolation of Personalized Aptamers for Monitoring Minimal Residual Disease in Multiple MyelomaR33CA196470 · NCI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI LIN, QIAO · 2016 to 2018
$1.2M
A Differential Dielectric Affinity Microsensor for Stable and Accurate Glucose MoDP3DK101085 · NIDDK · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI LIN, QIAO · 2013 to 2013
$1.1M
NCI NIH HHS R33 CA196470NIDDK NIH HHS DP3 DK101085
6 · The paper itself

Abstract

We present an approach for the label-free detection of cytokine biomarkers using an aptamer-functionalized, graphene-based field effect transistor (GFET) nanosensor on a flexible, SiO2-coated substrate of the polymer polyethylene naphthalate (PEN). The nanosensor conforms to the underlying nonplanar surface and performs GFET-based rapid transduction of the aptamer-biomarker binding, thereby potentially allowing the detection of cytokine biomarkers that are sampled reliably from human bodily fluids (e.g., sweat) in wearable sensing applications. In characterizing the suitability of the nanosensor for wearable applications, we investigate the effects of substrate bending on the equilibrium dissociation constant between the aptamer and the biomarker as well as the graphene transconductance. The utility of the nanosensor is demonstrated by the detection of tumor necrosis factor-α (TNF-α), an inflammatory cytokine biomarker. Experimental results show that the flexible nanosensor can specifically respond to changes in the TNF-α concentration within 5 minutes with a limit of detection as low as 26 pM in a repeatable manner.

Indexed as

Biosensing TechniquesAptamers, NucleotideBiomarkersGraphiteHumansLimit of DetectionSilicon DioxideTransistors, ElectronicTumor Necrosis Factor-alphaWearable Electronic DevicesAptamers, NucleotideBiomarkersGraphiteSilicon DioxideTumor Necrosis Factor-alpha

Identifiers

PMID30431030
PMCPMC7536116

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.