Evidence map›Paper›PMID 30427540›Full record

ArticleTransfusion2019

Evaluation of the National Healthcare Safety Network Hemovigilance Module for transfusion-related adverse reactions in the United States.

Chris Edens, Kathryn A Haass, Melissa Cumming, Anthony Osinski, Lynne O'Hearn, Kelly Passanisi, Lynn Eaton, Paul Visintainer, Alexandra Savinkina, Matthew J Kuehnert and 2 more

Abstract readEvaluation Study
In one paragraph

Article in Transfusion, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Point-of-Care Diagnostics in Coagulation Management.Sensors (Basel, Switzerland) · 2020
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors.

Chris EdensDivision of Healthcare Quality Promotion, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia.
Kathryn A HaassDivision of Healthcare Quality Promotion, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia.ORCID 0000-0003-0397-986X
Melissa CummingMassachusetts Department of Public Health, Boston, Massachusetts.
Anthony OsinskiMassachusetts Department of Public Health, Boston, Massachusetts.
Lynne O'HearnBaystate Medical Center, Springfield, Massachusetts.
Kelly PassanisiBaystate Medical Center, Springfield, Massachusetts.
Lynn EatonBaystate Medical Center, Springfield, Massachusetts.
Paul VisintainerBaystate Medical Center, Springfield, Massachusetts.
Alexandra SavinkinaDivision of Healthcare Quality Promotion, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia.
Matthew J KuehnertDivision of Healthcare Quality Promotion, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia.
Sridhar V BasavarajuDivision of Healthcare Quality Promotion, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia.
Chester AndrzejewskiMassachusetts Department of Public Health, Boston, Massachusetts.

Funding

Intramural CDC HHS CC999999
6 · The paper itself

Abstract

introductionThe National Healthcare Safety Network (NHSN) Hemovigilance Module (HM) collects data on the frequency, severity, and imputability of transfusion-associated adverse events. These events contribute to significant morbidity and mortality among transfusion patients. We report results from the first systematic assessment of eight attributes of the HM. MATERIALS AND

methodsStandard methods were used to assess the HM. Evaluation data included training materials, system modification history, and facility survey information. A concordance analysis was performed using data from the Baystate Medical Center's (Springfield, MA) electronic transfusion reporting system.

resultsIn 2016, system representativeness remained low, with 6% (277 of 4690) of acute care facilities across 43 jurisdictions enrolled in the HM. In 2016, 48% (2147 of 4453) and 89% (3969 of 4,453) of adverse reactions were reported within 30 and 90 days of the reaction date, respectively, compared to 21% (109 of 511) and 56% (284 of 511) in 2010, demonstrating improved reporting timeliness. Data quality from most reactions was adequate, with 10% (45 of 442) misclassified transfusion-associated circulatory overload reactions, and no incomplete transfusion-transmitted infection data reported from 2010 to 2013. When compared to the Baystate system to assess concordance, 43% (24 of 56) of NHSN-reported febrile reactions were captured in both systems (unweighted kappa value, 0.47; confidence interval, 0.33-0.61).

conclusionSince the 2010 HM pilot, improvements have led to enhanced simplicity, timeliness, and strengthened data quality. The HM serves an important and unique role despite incomplete adoption nationwide. Facility efforts to track and prevent transfusion-associated adverse events through systems like the NHSN HM are a key step toward improving transfusion safety in the United States.

Indexed as

Blood SafetyBlood TransfusionDelivery of Health CareRisk ManagementFemaleHumansMaleTransfusion ReactionUnited States

Identifiers

PMID30427540
PMCPMC6365173

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.